7 Configuration
Installation manual
24
EHFH03S18D
Daikin Altherma 3 R F
4P596803-1D – 2022.08
7.4 Menu structure: Overview installer settings
[A]
[A.2]
[A.2.1]
[A.2.2]
[A.2.2.6]
[A.3]
[A.3.1]
[A.3.1.1]
[A.3.2]
[A.3.3]
[A.4]
[A.4.4]
[A.5]
[A.5.1]
[A.7]
[A.6]
[A.6.3]
[A.6.2]
Installer settings
Language
System layout
Space operation
Domestic hot water (DHW)
Heat sources
System operation
Commissioning
Overview settings
System layout
Standard
Options
Capacities
Confirm layout
Space operation
LWT settings
Room thermostat
Operation range
Domestic hot water
Type
Disinfection
Maximum setpoint
SP mode
Weather-dependent curve
Heat sources
Backup heater
System operation
Auto restart
Preferential kWh rate
Pwr consumpt. control
Averaging time
Ext amb. sensor offset
Forced defrost
Commissioning
Test run
UFH screed dryout
Air purge
Actuator test run
Standard
Unit type
Compressor type
Indoor software type
Forced off contact
Unit control method
Number of LWT zones
Pump operation mode
Power saving possible
User interface location
Options
DHW operation
DHW tank type
Contact type main
Contact type add.
Digital I/O PCB
Demand PCB
External kWh meter
External kWh meter
DHW pump
External sensor
Leaving water
Main
Additional
Delta T source
Room thermostat
Room temp. range
Room temp. offset
Ext. room sensor offset
Operation range
Space heating OFF temp
Space cooling On temp
Disinfection
Disinfection
Operation day
Start time
Temperature target
Duration
Backup heater
Operation mode
BUH only ambient temp.
Equilibrium temp.
Prefer. kWh rate PS
Allowed heaters
Forced pump OFF
Pwr consmp ctrl
Mode
Type
Amp. value
Amp. limits for DI
kW value
kW limits for DI
Priority
Digital I/O PCB
Ext. backup heat src
Solar kit
Alarm output
Bottom plate heater
Main
LWT setpoint mode
Temperature range
Modulated LWT
Shut-off valve
Emitter type
[A.3.1.2]
Additional
LWT setpoint mode
Temperature range
Room temp. step
[A.3.1.3]
Delta T source
Heating
Cooling
Emergency
LAN adapter
Pump down
Disable protections
INFORMATION
Solar kit settings are shown but are NOT applicable for this
unit. Settings shall NOT be used or changed.
INFORMATION
Depending on the selected installer settings and unit type,
settings will be visible/invisible.