8 Configuration
Installer reference guide
48
ERGA04~08DAV3(A) + EHVH04+08S23DAV
Daikin Altherma – Low temperature split
4P499573-1A – 2018.11
8.2 Configuration wizard
After first power ON of the system, the user interface will guide you
using the configuration wizard. This way you can set the most
important initial settings. This way the unit will be able to run
properly. Afterwards, more detailed settings can be done via the
menu structure if required.
You can find a short overview of the settings in the configuration
here. All the settings can also be adjusted in the settings menu (use
the breadcrumbs).
For the setting… Refer to…
Language [7.1]
Time/date [7.2]
Hours —
Minutes
Year
Month
Day
System
Indoor unit type (read only) "8.4.9Installer settings"on
page65
Backup heater type [9.3.1]
Domestic hot water [9.2.1]
Emergency [9.5]
Number of zones [4.4] "8.4.5Space heating"on
page57
Booster heater
Capacity [9.4.1] "Anti-legionella heater"on
page66
BSH allowance schedule [9.4.2]
BSH eco timer [9.4.3]
Operation [9.4.4]
Main zone
Emitter type [2.7] "8.4.3Main zone"on
page53
Control [2.9]
Setpoint mode [2.4]
Heating WD curve [2.5] (if
applicable)
Schedule [2.1]
Additional zone (only if [4.4]=1)
Emitter type [3.7] "8.4.4Additional zone"on
page56
Control (read only) [3.9]
Setpoint mode [3.4]
Heating WD curve [3.5] (if
applicable)
Schedule [3.1]
Tank
Heat up mode [5.6] "8.4.6Tank"on page60
Comfort setpoint [5.2]
Eco setpoint [5.3]
Reheat setpoint [5.4]
8.3 Possible screens
8.3.1 Possible screens: Overview
The most common screens are as follows:
a Home screen
b Main menu screen
c Lower level screens:
c1: Setpoint screen
c2: Detailed screen with values
8.3.2 Home screen
Press the
button to go back to the home screen. You see an
overview of the unit configuration and the room and setpoint
temperatures. Only symbols applicable for your configuration are
visible on the home screen.
6
1.6
bar
18 Feb 2018
22:19
55
18
21
45
f
i
j
h
g
e
d
a
b
c
Possible actions on this screen
Go through the list of the main menu.
Go to the main menu screen.
Enable/disable breadcrumbs.
Item Description
The temperatures are shown in circles. If the circle
is grey, the corresponding operation (example:
space heating) is currently not active.
Outdoor
unit
a1
: Outdoor unit
a2
: Quiet mode active
a3 Measured ambient temperature
Indoor unit /
domestic
hot water
tank
b1 Indoor unit:
▪
: Floor-standing indoor unit with
integrated tank
b2 Water pressure
Space
operation
mode
c
: Heating