Installation and
maintenance instructions
Daikin Altherma M ECH
2
O
EKHWMX300C
EKHWMXB300C
EKHWMX500C
EKHWMXB500C
Installation and
maintenance instructions
Solar storage tank with heating
English
07/2019

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Daikin Altherma M ECH2O Series and is the answer not in the manual?

Daikin Altherma M ECH2O Series Specifications

General IconGeneral
CategoryHeat Pump
RefrigerantR-32
Integrated Solar OptionYes
Domestic Hot Water Tank MaterialStainless Steel
Operating Temperature Range (Heating)-25°C to 35°C
Operating Temperature Range (Cooling)10°C to 46°C
ModelDaikin Altherma M ECH2O Series
TypeAir-to-Water Heat Pump
Heating Capacity4.0 - 16.0 kW
Cooling Capacity4.0 - 14.0 kW
Water Tank Capacity300L / 500L (integrated)
Energy Efficiency Class (Heating)A+++
Energy Efficiency Class (Cooling)A++
Sound Power Level (Outdoor Unit)58-65 dB(A) (depending on model)

Summary

General Information

Refer to the Manual

Advises users to read the manual thoroughly before installation or modification for safe operation.

Warranty Conditions

Outlines the warranty conditions and where to find further details online.

Safety Precautions

Warnings and Symbols Explained

Details the meaning of warning symbols (Danger, Warning, Caution) and special danger signs.

Avoiding Danger

Provides guidance on safe installation and operation to prevent serious injury or damage.

Intended Use and Combinations

Specifies the authorized uses and permissible combinations of indoor and outdoor units.

Operating Safety Instructions

Covers safety guidelines for hydraulic system work, electrical installation, and general operation.

Product Description

Design and Components Overview

Details the exterior and interior structure of the EKHWMX(B)300C and EKHWMX(B)500C models.

Set-up and Installation

Dimensions and Connections

Illustrates unit dimensions and connection points for EKHWMX(B)300C and EKHWMX(B)500C models.

Installation and Site Preparation

Covers scope of delivery, general installation precautions, and site requirements.

Cover and Insulation Removal

Provides instructions for safely removing protective covers and thermal insulation.

Water Connections

Details water connection procedures, including pipe alignment and hydraulic line setup.

Electrical Connections

Outlines electrical connection safety, overall diagrams, PCB locations, and mains connections.

Auxiliary and System Connections

Guides on connecting external devices like room thermostats, RoCon components, and Smart Grid systems.

Wiring Diagram Symbols and Keys

Explains symbols and key names used in connection and wiring diagrams for clarity.

Start-up Procedures

Initial Start-up Steps

Outlines the initial steps and requirements for starting up the Daikin Altherma M ECH2O.

Pre-Start-up Requirements

Lists the prerequisites that must be met before initiating the start-up process.

Device Power-up and Language Selection

Describes powering on the unit and selecting the operating language.

Setting Commissioning Parameters

Guides technicians on setting essential commissioning parameters via the controller.

Bleeding the Hydraulic System

Provides instructions for removing air from the hydraulic system for optimal operation.

Checking Minimum Water Flow

Explains how to verify adequate water flow rates for system performance.

Screed Program Setup

Details setting the screed program for controlled feed temperature profiles.

Re-commissioning Process

Covers procedures for re-commissioning the system, including requirements and start-up.

Taking Out of Operation

Temporary Shutdown Procedures

Provides instructions for temporarily shutting down the system, including draining.

Draining the Storage Tank

Details the process for safely draining water from the storage tank.

Draining Heating and Hot Water Circuits

Guides on how to drain the heating and hot water circuits of the system.

Final Shutdown and Disposal

Explains the procedure for permanently decommissioning and disposing of the unit.

Service and Maintenance

General Maintenance Guidelines

Emphasizes regular inspection and maintenance for efficiency and longevity.

Annual Maintenance Tasks

Lists essential annual maintenance tasks to be performed by qualified personnel.

Filling and Topping Up Storage Tank

Provides instructions for filling and topping up the storage tank with water.

Filling and Topping Up Heating System

Details the procedure for filling the heating system, including frost protection measures.

Preventing Water Circuit Freezing

Explains how to protect the water circuit from freezing using glycol or system functions.

Filling and Topping Up Steps

Provides step-by-step instructions for filling and topping up the heating system.

Errors, Malfunctions, and Messages

Recognizing and Correcting Errors

Guides on identifying and rectifying errors, malfunctions, and messages displayed by the controller.

Current Error Display Interpretation

Explains how error messages are presented on the unit's controller.

Accessing the System Protocol

Details how to access and interpret the system's error and status protocol.

Troubleshooting Common Issues

Offers guidance on resolving common malfunctions and error conditions.

Malfunction Causes and Solutions

Lists common malfunctions, their potential causes, and recommended corrective actions.

Error Codes Reference

Provides a comprehensive list of error codes, their meanings, and troubleshooting steps.

DIP Switch Configuration and Control

Explains the setup and control of DIP switches on the RoCon BM2C circuit board.

Emergency Operation Mode

Describes how to activate emergency heating operation and adjust related settings.

Hydraulic System Connection

Technical Data

Equipment Specifications

Provides detailed technical data for EKHWMX(B)300C and EKHWMX(B)500C models.

EKHWMX(B)300C Model Data

Lists technical specifications, dimensions, and operating data for the EKHWMX(B)300C.

EKHWMX(B)500C Model Data

Lists technical specifications, dimensions, and operating data for the EKHWMX(B)500C.

Type Plate Information Details

Explains the information provided on the unit's type plate for identification.

Characteristic Lines and Curves

Presents characteristic curves for sensors and pressure readings.

Sensor Characteristic Curves

Shows characteristic curves for temperature and pressure sensors.

Tightening Torque Specifications

Lists the recommended tightening torques for various components during installation.

Electrical Circuit Diagram

Displays the overall electrical circuit diagram for the Daikin Altherma M ECH2O system.