Open the front panel and pull out the air filter downwards.
Unfasten hooks to remove Titanium apatite filters from their frame.
Carefully remove the horizontal blade after releasing all shafts.
Remove the front panel after releasing its rotary shafts.
Remove screw, disconnect earth wire, thermistor, and connector [S200].
Remove screws, disconnect drain hose, and flare nuts for piping.
Lift and pull indoor heat exchanger to unfasten hooks and remove it.
Open the front panel and pull out the air filter downwards.
Unfasten hooks to remove Titanium apatite filters from their frame.
Carefully remove the horizontal blade after releasing all shafts.
Remove the front panel after releasing its rotary shafts.
Remove screw, disconnect earth wire, thermistor, and connector [S200].
Remove screws, disconnect drain hose, and flare nuts for piping.
Lift and pull indoor heat exchanger to unfasten hooks and remove it.
| Cooling Capacity | 3.5 kW |
|---|---|
| Heating Capacity | 4.0 kW |
| Refrigerant | R32 |
| Weight (Outdoor Unit) | 30 kg |
| Star Rating | 5 Star |
| Type | Split Air Conditioner |
| Energy Efficiency Ratio (Cooling) | 3.51 W/W |
| Power Supply | 220-240V, 50 Hz |