REMOVAL
PROCEDURE
SERVICE MANUAL
Indoor Unit
Inverter
Wall Mounted Type
1.5/2.0/2.5/3.0/3.5 kW Class
9000/12000 Btu/h Class
Si041264EC
Question and Answer IconNeed help?

Do you have a question about the Daikin ATKC12RV2S and is the answer not in the manual?

Summary

Air Filters Removal

Remove Air Filters

Open the front panel and pull out the air filter downwards.

Remove Photocatalytic Filters

Unfasten hooks to remove Titanium apatite filters from their frame.

Horizontal Blade Removal

Remove Horizontal Blade

Carefully remove the horizontal blade after releasing all shafts.

Front Panel Removal

Remove Front Panel

Remove the front panel after releasing its rotary shafts.

Electrical Box and Vertical Blades

Remove Electrical Box

Remove screw, disconnect earth wire, thermistor, and connector [S200].

Swing Motor and PCBs Removal

Indoor Heat Exchanger Removal

Disconnect Refrigerant Piping

Remove screws, disconnect drain hose, and flare nuts for piping.

Remove Indoor Heat Exchanger

Lift and pull indoor heat exchanger to unfasten hooks and remove it.

Fan Rotor and Fan Motor Removal

Summary

Air Filters Removal

Remove Air Filters

Open the front panel and pull out the air filter downwards.

Remove Photocatalytic Filters

Unfasten hooks to remove Titanium apatite filters from their frame.

Horizontal Blade Removal

Remove Horizontal Blade

Carefully remove the horizontal blade after releasing all shafts.

Front Panel Removal

Remove Front Panel

Remove the front panel after releasing its rotary shafts.

Electrical Box and Vertical Blades

Remove Electrical Box

Remove screw, disconnect earth wire, thermistor, and connector [S200].

Swing Motor and PCBs Removal

Indoor Heat Exchanger Removal

Disconnect Refrigerant Piping

Remove screws, disconnect drain hose, and flare nuts for piping.

Remove Indoor Heat Exchanger

Lift and pull indoor heat exchanger to unfasten hooks and remove it.

Fan Rotor and Fan Motor Removal

Daikin ATKC12RV2S Specifications

General IconGeneral
Cooling Capacity3.5 kW
Heating Capacity4.0 kW
RefrigerantR32
Weight (Outdoor Unit)30 kg