EasyManua.ls Logo

Daikin ATXB35C2V1B - User Manual

Daikin ATXB35C2V1B
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
DAIKIN ROOM AIR CONDITIONER
OPERATION MANUAL
MODELS
ATXB25C2V1B
ATXB35C2V1B

Other manuals for Daikin ATXB35C2V1B

Questions and Answers

  • R
    rjohnsonSep 8, 2025
    What to do if the safety breaker cuts off the operation of Daikin ATXB35C2V1B frequently?
    • K
      kaufmanerinSep 8, 2025
      If the safety breaker, a fuse, or the earth leakage breaker cuts off the operation of your Daikin Air Conditioner frequently, it's recommended to immediately call the service shop.
  • A
    Ashley HardinAug 23, 2025
    Why Daikin Air Conditioner does not operate and OPERATION lamp is off?
    • P
      Paul GonzalesAug 23, 2025
      If your Daikin Air Conditioner isn't operating and the OPERATION lamp is off, check these items: * Confirm that a breaker hasn’t turned off or a fuse blown. * Ensure there isn’t a power failure. * Verify that batteries are correctly installed in the remote controller. * Check if the timer setting is correct.
  • M
    Michelle MercadoAug 25, 2025
    What to do if water leaks from Daikin ATXB35C2V1B Air Conditioner indoor unit?
    • D
      Derrick CherryAug 26, 2025
      If you notice water leaking from the indoor unit of your Daikin Air Conditioner, it's recommended to immediately call the service shop.
  • A
    Amy GallagherAug 26, 2025
    Why is my Daikin ATXB35C2V1B cooling (heating) effect poor?
    • M
      Mark TuckerAug 26, 2025
      If your Daikin Air Conditioner is not cooling (or heating) effectively, consider the following: * Ensure that the air filters are clean. * Check for any obstructions blocking the air inlet or outlet of both the indoor and outdoor units. * Verify that the temperature setting is appropriate for your needs. * Make sure all windows and doors are closed properly. * Confirm that the airflow rate and direction are set correctly.
  • C
    cameron07Aug 27, 2025
    Why is there a burning smell coming from my Daikin Air Conditioner?
    • T
      Thomas MitchellAug 27, 2025
      If you notice a burning smell coming from your Daikin Air Conditioner, it's recommended to immediately call the service shop.
  • A
    Andrea GrossSep 22, 2025
    Why the outdoor fan of Daikin ATXB35C2V1B rotates while the air conditioner is not in operation?
    • S
      shawn44Sep 22, 2025
      The outdoor fan of your Daikin Air Conditioner continues rotating for another 60 seconds for system protection. When the outdoor temperature is very high, the outdoor fan starts rotating for system protection.
  • S
    Sheila MillerSep 16, 2025
    What to do if Daikin Air Conditioner operation stopped suddenly and OPERATION lamp is on?
    • C
      Chad NealSep 16, 2025
      If your Daikin Air Conditioner's operation stopped suddenly but the OPERATION lamp is on, it will automatically resume operation in about 3 minutes.
  • L
    Lisa MeyerSep 18, 2025
    How to fix Daikin Air Conditioner flap that does not start swing immediately?
    • A
      Angelica WilsonSep 18, 2025
      The flap of your Daikin Air Conditioner will start moving soon. The air conditioner may also be adjusting the flap position.
  • C
    crystal69Sep 7, 2025
    What to do if a switch or a button often fails to work properly on Daikin ATXB35C2V1B?
    • J
      johnweissSep 7, 2025
      If a switch or button on your Daikin Air Conditioner often fails to work properly, it's recommended to immediately call the service shop.
  • K
    Keith ArmstrongSep 4, 2025
    What to do if I hear abnormal sound during Daikin Air Conditioner operation?
    • K
      Katherine MccarthySep 4, 2025
      If you hear an abnormal sound during the operation of your Daikin Air Conditioner, it's recommended to immediately call the service shop.

Summary

Safety Precautions

Names of Parts

Indoor Unit

Identifies components of the indoor unit including filters, sensors, and outlets.

Outdoor Unit

Identifies components of the outdoor unit, such as air inlets, outlets, and piping.

Preparation before Operation

To set the batteries

Steps for inserting batteries into the remote controller.

To operate the remote controller

Guidelines for aiming the remote controller transmitter at the indoor unit.

To fix the remote controller holder on the wall

Instructions for mounting the remote controller holder securely on a wall.

AUTO DRY COOL HEAT FAN Operation

To start operation

How to select and begin operating the air conditioner using the remote.

To stop operation

How to turn off the air conditioner using the ON/OFF button.

To change the temperature setting

Adjusting the desired temperature for cooling or heating.

Adjusting the Airflow Direction

To start auto swing

Initiating automatic swinging of the horizontal flap for air distribution.

To set the flap at desired position

Stopping the flap at a specific angle while in auto swing mode.

To adjust the louvers (vertical blades)

Manual adjustment of the vertical louvers for directional airflow.

COMFORT AIRFLOW Operation

To start COMFORT AIRFLOW operation

Activating the mode for gentle, indirect airflow.

To cancel COMFORT AIRFLOW operation

Deactivating the COMFORT AIRFLOW mode.

POWERFUL Operation

To start POWERFUL operation

Engaging the mode for maximum cooling or heating effect.

To cancel POWERFUL operation

Disengaging the POWERFUL operation mode.

ECONO Operation

To start ECONO operation

Activating the energy-saving mode to limit power consumption.

To cancel ECONO operation

Deactivating the ECONO operation mode.

OFF TIMER Operation

To use OFF TIMER operation

Instructions for setting the timer to automatically switch the unit off.

To cancel OFF TIMER operation

Cancelling a previously set OFF timer.

ON TIMER Operation

To use ON TIMER operation

Instructions for setting the timer to automatically switch the unit on.

To cancel ON TIMER operation

Cancelling a previously set ON timer.

To combine ON TIMER and OFF TIMER

Using both ON and OFF timers simultaneously for scheduled operation.

Care and Cleaning

Indoor unit and remote controller

Instructions for wiping the indoor unit and remote controller with a dry cloth.

Front panel

Procedures for opening, removing, and cleaning the front panel of the indoor unit.

Filters

Guidance on cleaning and replacing the air filters and air-purifying filters.

Troubleshooting

Daikin ATXB35C2V1B Specifications

General IconGeneral
TypeAir conditioner indoor unit
Ionizer-
Multi-splitYes
Product colorWhite
Compressor typeRotary
Gas hose diameter9.5 mm
Hose length (max)15 m
Drain hose diameter18 mm
Liquid hose diameter6.35 mm
Refrigerating mediumR410A
Cooling capacity (max)13000 BTU/h
Cooling capacity (min)4400 BTU/h
Heating capacity (max)16300 BTU/h
Timer duration (maximum)24 h
Air conditioner functionsCooling, Dehumidifying, Fan, Heating
Cooling capacity in watts (max)3800 W
Cooling capacity in watts (min)1300 W
Heating capacity in watts (max)4800 W
Cooling capacity in watts (nominal)3300 W
Cooling energy efficiency (EER, W/W)3.21
Heating energy efficiency (COP, W/W)3.71
Operating temperature (cooling) (T-T)-10 - 46 °C
Operating temperature (heating) (T-T)-15 - 18 °C
Seasonal efficiency rating (cooling) (SEER)6.02
Heating capacity in watts (nominal) (Warmer heating season)- W
Heating capacity in watts (nominal) (Average heating season)3500 W
Seasonal efficiency rating (heating) (SCOP) (Average heating season)4.04
Current1 A
AC input voltage220 - 240 V
AC input frequency50 Hz
Design load (cooling)3.3 kW
Power consumption (cooling) (max)1030 W
Power consumption (heating) (max)940 W
Annual energy consumption (cooling)192 kWh
Hourly energy consumption (cooling)- kWh
Design load (heating) (Warmer heating season)- kW
Design load (heating) (Average heating season)2.8 kW
Energy efficiency class (heating) (Average heating season)A+
Annual energy consumption (heating) (Average heating season)970 kWh
Indoor unit typeWall-mountable
Indoor unit depth216 mm
Indoor unit width770 mm
Indoor unit height283 mm
Indoor unit weight8000 g
Indoor units quantity1
Cooling airflow (indoor unit)462 m³/h
Heating airflow (indoor unit)504 m³/h
Indoor unit noise level (low speed)23 dB
Indoor unit noise level (high speed)58 dB
Outdoor unit noise level- dB