Perform the following operation to pre-
vent heating capacity decrease and dis-
charge of cool air.
AT THE START OF OPERATION AND
AFTER DEFROST OPERATION
A warm air circulating system is employed,
and therefore it takes some time until the
entire room is warmed up after the start of
operation.
The indoor fan runs to discharge a gentle
wind automatically until the temperature
inside the air conditioner reaches a certain
level. At this time, the DEFROST OPERA-
TION LAMP for the light receiving unit indi-
cator lights. Leave it as it stands and wait
for a while.
(The remote controller displays the airflow
rate that is set.)
The air discharge direction becomes hori-
zontal to prevent a draft of cool air to the
inhabitants (The remote controller will dis-
play the set air discharge direction)
DEFROST OPERATION (Frost removal
operation for the outdoor unit)
As the frost on the coil of an outdoor unit
increase, heating effect decreases and the
system goes into DEFROST OPERA-
TION.
The warm air stops, and the DEFROST
OPERATION LAMP for the light receiving
unit indicator lights. (The remote controller
displays the airflow rate that is set.)
After 6 to 8 minutes (maximum 10 min-
utes) of DEFROST OPERATION, the sys-
tem returns to HEATING OPERATION.
The air discharge direction becomes hori-
zontal. (The remote controller displays the
airflow direction that is set.)
When the operation is switched to the
HEATING OPERATION during or after the
DEFROST OPERATION, white mist
comes out from the air outlet of the outdoor
unit.
A hissing and “Shuh” sound may be heard
during this particular operation.
Regarding outside air temperature
and heating capacity
The heating capacity of the air conditioner
declines as the outside air temperature
falls. In such a case, use the air conditioner
in combination with other heating systems.
(When a combustion appliance is used,
ventilate the room regularly.)
Do not use the combustion appliance
where the air from the air conditioner is
blown directly toward it.
When the warm air stays under the ceiling
and your feet are cold, we recommend that
you use a circulator (a fan to circulate the
air inside the room). For details, consult
your dealer.
When the indoor temperature exceeds the
set temperature, the air conditioner dis-
charges a gentle breeze (switches to whis-
per mode). The air discharge direction
becomes horizontal. (The remote control-
ler displays the airflow rate and airflow
direction that are being set.)
[CHARACTERISTICS OF THE PRO-
GRAM DRY OPERATION]
This operation lowers the humidity without
lowering the indoor temperature. The
indoor temperature when the operation
button is pressed will be the set tempera-
ture. At this time, the airflow rate and
humidity are set automatically, so the
remote controller does not display the air-
flow rate and set temperature.
To efficiently lower the indoor temperature
and humidity, first lower the indoor temper-
ature using the COOLING OPERATION,
and then use PROGRAM DRY OPERA-
TION. When the indoor temperature is
lowered, air discharge from the air condi-
tioner may stop.
After continued operation at a downward
airflow direction, operate the air condi-
tioner using a different direction setting for
a period of time to prevent condensation
on the airflow flaps. (The remote controller
displays the airflow direction that is set.)