Model Number | DZ16TC0601CA |
---|---|
Category | Air Conditioner |
Brand | Daikin |
Series | ComfortNet |
SEER Rating | 16 |
Energy Efficiency Ratio (EER) | 12.5 |
Refrigerant Type | R-410A |
Compressor Type | Scroll |
Stages | Single-stage |
Voltage | 208/230V |
Phase | 1 |
Frequency | 60 Hz |
Outdoor Unit Type | Condensing Unit |
Warranty | 10 years |
Cooling Capacity | 60000 BTU |
Guidelines for safe handling of refrigerants, including breathing hazards and cold burns.
Warning about using returnable service cylinders for refrigerant removal.
Explanation of the defrost cycle operation for ComfortNet models.
Procedure for checking voltage supply to the unit.
Troubleshooting steps for ComfortNet system network issues.
Table listing 7-segment LED codes and their corresponding conditions.
Diagnostic codes for motor failure and airflow issues.
Diagnostic codes for motor lock-rotor, voltage, and parameter errors.
Procedure for testing the unit's transformer and control circuit.
Procedure for checking voltage supply to the ECM motor.
Diagnostics for Copeland Comfort Alert system integrated into the UC control.
Table detailing abnormal operation symptoms and diagnostic codes.
Table of unitary diagnostic codes for voltage and protector faults.
Procedure for checking the high pressure control operation.
Procedure for checking capacitor capacitance with a digital multi-meter.
Instructions for using the Emerson UltraCheck-EZ diagnostic tool.
Procedure for checking low voltage control circuit voltages.
Guide to ECM CFM adjustments using dipswitches for DVPTC/MBVC models.
Safety warnings and procedures for checking compressors.
Procedure for testing the unloader function with Comfort Alert.
Procedure for testing temperature sensors on ComfortNet ready models.
Procedure for leak testing refrigeration systems.
Procedures and warnings for charging the system with refrigerant.
Procedure for checking compressor efficiency.
Procedure for checking subcooling and refrigerant charge.
Procedure to check compressor efficiency by examining performance test results.
Procedure for diagnosing and addressing compressor burnout.
Procedure for visually inspecting and checking wiring for damage.
Chart detailing LED status, causes, and corrective actions for network issues.
Procedure for checking the low pressure control operation.
General checks and considerations for Emerson Ultratech ECM motors.
Procedure for checking high voltage power circuits for safety.
Checks for the motor control and end bell components.
Procedure for testing compressor winding resistance.
Operation test procedure if other tests fail to identify the cause.
Procedure for evacuating the system to remove moisture and air.
Procedure for checking the operation of the expansion valve.
Procedure for checking the compressor contactor/relay contacts on the UC control.
Procedure for checking voltage at high and low pressure switches.
Safety precautions before performing motor checks.
Procedure for performing a ground test on the compressor.
Explanation of run capacitor function and testing.
General practices and safety for refrigeration system repairs.
Procedure for checking superheat and related expansion valve adjustments.
Procedure for checking capacitor resistance with a digital multi-meter.