7 Error codes
Operation manual
9
D2CNL024A1AA
Wall-mounted condensing boiler
3P469438-12N – 2020.07
# Problem Solution
1J-64 High limit thermostat
signalise overheating
Check the valves of the radiators
in the heating circuit.
Check the combi boiler water
pressure. If it is low, fill the heating
circuit with water.
Perform reset. If problem repeats,
contact your service agent.
80-01 Return temperature
sensor fault
Perform reset. If problem repeats,
contact your service agent.
81-01 Flow temperature
sensor fault
Perform reset. If problem repeats,
contact your service agent.
81-65 Domestic hot water
solar temperature
sensor fault
Boiler continues operation but solar
sensor is defective. Contact your
service agent.
8A-46 Freeze protection Unit does not operate if flow
temperature sensor reads value less
than 1°C. Wait until the error code is
removed from the screen.
8H-64 Flow temperature
steep rise
Make sure radiator valves are open
enough to circulate water. Your
boiler will operate again after a while.
If problem repeats, contact your
service agent.
8H-65 Flow-return
temperature
difference too much
Make sure radiator valves are open
enough to circulate water. If problem
repeats, contact your service agent.
E1-64 Flame detection
before burner
operation
Perform reset. If problem repeats,
contact your service agent.
E1-69 Parameter CRC error Perform reset. If problem repeats,
contact your service agent.
E1-71 EK lockout failure Permanent error. Contact your
service agent.
E1-73 Internal PCB error Perform reset if needed. If problem
repeats, contact your service agent.
H9-01 Outside sensor fault Boiler continues operation but
outside sensor is defective. Contact
your service agent.
HC-01 Domestic hot water
temperature sensor
fault
Boiler continues operation but you
must contact your service agent.
HJ-08 High system pressure Discharge water down to 0.8bar.
(You can bleed the radiators.)
HJ-09 Low system pressure Increase the system pressure to
0.8bar
HJ-10 Water pressure
sensor fault
Contact your service agent.
J6-01 Flow temperature
sensor overheating
(Can be a blocking
error or a lockout
error)
Check the valves of the radiators
in the heating circuit.
Check the combi boiler water
pressure. If it is low, fill the heating
circuit with water.
Perform reset if needed. If problem
repeats, contact your service
agent.
J6-21 Return temperature is
higher than flow
temperature
No reset needed, burner operates
itself after a small amount of time. If
problem repeats, contact your
service agent.
JJ-64 Flue temperature
sensor fault
Perform reset. If problem repeats,
contact your service agent.
# Problem Solution
U4-67 Remote reset
supervision
Switch off - switch on power mains. If
problem repeats, contact your
service agent.