14



1 2 3 4 5 6 7 8
2 75 70 65 60 55 50 45 40
3 114 107 100 93 86 79 72 65
2 45 40 35 30 25 20 15 10
3 168 161 154 147 140 133 126 119
2 35 30 25 20 15 10 5 N/A
3 168 161 154 147 140 133 126 119
2 60 55 50 45 40 35 30 25
3 113 106 99 92 85 78 71 64
2 45 40 35 30 25 20 15 10
3 120 113 106 99 92 85 78 71
2 40 35 30 25 20 15 10 5
3 151 144 137 130 123 116 109 102
2 N/A N/A N/A N/A N/A N/A N/A N/A
3 158 151 144 137 130 123 116 109
2 100 95 90 85 80 75 70 65
3 137 130 123 116 109 102 95 88
2 45 40 35 30 25 20 15 10
3 168 161 154 147 140 133 126 119
2 40 35 30 25 20 15 10 5
3 120 113 106 99 92 85 78 71
2 N/A N/A N/A N/A N/A N/A N/A N/A
3 113 106 99 92 85 78 71 64
2 N/A N/A N/A N/A N/A N/A N/A N/A
3 110 103 96 89 82 75 68 61



























1 2 3 4 5 6 7 8
2 75 70 65 60 55 50 45 40
3 114 107 100 93 86 79 72 65
2 55 50 45 40 35 30 25 20
3 127 120 113 106 99 92 85 78
2 30 25 20 15 10 5 N/A N/A
3 72 65 58 51 44 37 30 23
2 30 25 20 15 10 5 N/A N/A
3 72 65 58 51 44 37 30 23
2 40 35 30 25 20 15 10 5
3 72 65 58 51 44 37 30 23
2 60 55 50 45 40 35 30 25
3 168 161 154 147 140 133 126 119
2 30 25 20 15 10 5 N/A N/A
3 113 106 99 92 85 78 71 64
2 N/A N/A N/A N/A N/A N/A N/A N/A
3 65 58 51 44 37 30 23 16

























1. Maximum allowable limits listed on individual lengths
for inlet and ue and NOT a combination.
2. Minimum requirement for each vent pipe if ve (5)
feet in length and one elbow/tee.
3. Tee used in the vent/ue termination must be
included when determining the number of elbows in
the piping system.
4. 2 ½” or 3” diameter pipe can be used in place of 2”
diameter pipe.
5. Increased Clearance Conguration using (2) 45
deg. Long Sweep elbows should be considered
equivalent to one 90 deg. elbow.
6. One 90° elbow should be secured to the combustion
air intake connection.