Do you have a question about the Daikin DZ17VSA421AA and is the answer not in the manual?
Model Number | DZ17VSA421AA |
---|---|
Category | Heat Pump |
Cooling Capacity (BTU) | 42000 |
Cooling Capacity (Ton) | 3.5 |
SEER Rating | 17 |
HSPF Rating | 9.5 |
Heating Capacity (BTU) | 42000 |
Heating Capacity (Ton) | 3.5 |
Voltage | 208/230 |
Phase | 1 |
Refrigerant | R-410A |
Sound Level (dB) | 74 |
Compressor Type | Inverter |
Stages | Variable |
Only trained personnel should service the equipment. Manufacturer not responsible for improper service.
Warning about cancer and reproductive harm from chemical exposure.
Do not wash the heat pump with excessive water to avoid shock or fire.
Required clearances for 1.5-3.0 ton and 3.5-5.0 ton single unit installations.
Required clearances for two unit installations.
Read safety instructions before installation; use licensed installers.
Safe handling of refrigerants, including purging and ventilation.
Precautions for using returnable service cylinders for refrigerant.
Keep R410A clean, dry, tight; prevent contamination.
Warnings on improper grounding, disposal, qualified personnel, and foundation strength.
Cautions on PVE oil, tubing, and line insulation.
Notes on brazing, nitrogen purging, and filter drier installation.
Warnings and steps for leak testing with dry nitrogen.
Warnings against overcharging and operating in vacuum.
Caution against operating with suction valve closed.
Steps for vacuuming, leak testing, and initial start-up.
High voltage, wiring, and conductor requirements.
Formula and tables for calculating refrigerant charge based on line set length and diameter.
Instructions for measuring subcooling to confirm correct refrigerant charge.
Warning about high voltage during servicing or installation.
Avoid contact with charged areas; discharge static electricity.
Table listing possible causes and indicators for heating system analysis.
Details probable causes and corrective actions for specific fault codes.
Troubleshooting communication network issues, LEDs, and dipswitches.
Pre-start-up checklist for installers to verify correct installation procedures.
Instructions on initiating and running the system verification test.
Continues the procedure for running and completing the system start-up test.
Procedure to enter CHARGE MODE for system charging and subcooling adjustment.
Continues the procedure for initiating and terminating CHARGE MODE.
Instructions for measuring subcooling to confirm correct refrigerant charge.
Mandatory system verification test for equipment functionality.