10 | Configuration
Installer reference guide
196
EPRA08~12EAV3+W1 + ETVH12SU18+23EA6V
Daikin Altherma 3 H MT F
4P644482-1 – 2021.03
# Code Description
[8.A] N/A Reset the MMI EEPROM
to factory default
Possible read-out information
In menu… You can read out…
[8.1] Energy data Produced energy, consumed electricity,
and consumed gas
[8.2] Malfunction history Malfunction history
[8.3] Dealer information Contact/helpdesk number
[8.4] Sensors Room, tank or domestic hot water,
outside, and leaving water temperature
(if applicable)
[8.5] Actuators Status/mode of each actuator
Example: Domestic hot water pump
ON/OFF
[8.6] Operation modes Current operation mode
Example: Defrost/oil return mode
[8.7] About Version information about the system
[8.8] Connection status Information about the connection
status of the unit, the room thermostat
and the LAN adapter.
[8.9] Running hours Running hours of specific system
components
10.5.9 Installer settings
Overview
The following items are listed in the submenu: