Installer reference guide
Daikin Altherma 3 R F
ERGA04DAV3(A)
ERGA06DAV3(A)
ERGA08DAV3(A)
EHVH04S18D*6V7
EHVH04S23D*6V7
EHVH08S18D*6V7
EHVH08S23D*6V7
EHVH08S18D*9W7
EHVH08S23D*9W7
EHVX04S18D*3V7
EHVX04S18D*6V7
EHVX04S23D*3V7
EHVX04S23D*6V7
EHVX08S18D*6V7
EHVX08S23D*6V7
EHVX08S18D*9W7
EHVX08S23D*9W7

Table of Contents

Other manuals for Daikin ERGA08DAV3A

Questions and Answers

  • S
    stevenriveraAug 18, 2025
    Why is my Daikin ERGA08DAV3A not sufficiently heating at low outdoor temperatures?
    • L
      Lindsay MckenzieAug 18, 2025
      If your Daikin Heat Pump isn't sufficiently heating the space at low outdoor temperatures, it could be due to several reasons: * The backup heater operation might not be activated. Ensure the backup heater operation mode is enabled. * The backup heater overcurrent circuit breaker might be off. Turn it back on if it is off. * The thermal protector of the backup heater might be activated. If it has, check the water pressure, whether there is air in the system, and the air purge operation, then press the reset button in the switch box. * The backup heater equilibrium temperature may not be configured correctly. Try increasing the equilibrium temperature to activate the backup heater operation at a higher outdoor temperature.
  • C
    charlesjohnsonAug 20, 2025
    How to check temperature settings on Daikin ERGA08DAV3A when it is not heating or cooling?
    • D
      Dennis JenningsAug 20, 2025
      If your Daikin Heat Pump isn't heating or cooling as expected, first check the temperature setting on the remote controller to ensure it's correct. The issue might stem from an incorrect setting.
  • T
    Thomas MccartyAug 22, 2025
    What to do if Daikin ERGA08DAV3A is not heating or cooling and water flow is low?
    • K
      Kim SnyderAug 23, 2025
      If your Daikin Heat Pump isn't heating or cooling as expected, it might be due to low water flow. Ensure all shut-off valves of the water circuit are completely open, the water filter is clean, and there is no air in the system. Also, check that the water pressure is above 1 bar, the expansion vessel is not broken, and the valve towards the expansion vessel is open. Verify that the resistance in the water circuit isn't too high for the pump.
  • L
    Linda Nichols MDAug 26, 2025
    Why won't the compressor start on my Daikin ERGA08DAV3A Heat Pump for space or water heating?
    • A
      Adam KellyAug 26, 2025
      If the compressor in your Daikin Heat Pump isn't starting for space or domestic water heating, it could be because the unit is starting outside of its operation range, meaning the water temperature is too low. In this case, the unit uses the backup heater to reach the minimum water temperature first (15°C). Check that the power supply to the backup heater is correctly wired, and the backup heater thermal protector is not activated, and the backup heater contactors are not broken.
  • H
    hendrixaaronAug 28, 2025
    Why is my Daikin ERGA08DAV3A system making gurgling noises?
    • H
      Heather OdomAug 28, 2025
      If your Daikin Heat Pump system is making gurgling noises after commissioning, it could be caused by air in the system. Purge the air from the system. It can also be caused by various malfunctions. Check if or is displayed on the home screen of the user interface for more information about the malfunction.
  • D
    Dorothy MooreAug 30, 2025
    How to fix a noisy pump (cavitation) in my Daikin ERGA08DAV3A Heat Pump?
    • N
      Nathaniel GonzalezAug 30, 2025
      If the pump in your Daikin Heat Pump is making noise (cavitation), it could be due to air in the system. Purge the air manually or use the automatic air purge function. Another possible cause is that the water pressure at the pump inlet is too low. Ensure the water pressure is above 1 bar, the water pressure sensor is not broken, the expansion vessel is not broken, the valve of the water circuit towards the expansion vessel is open, and the pre-pressure setting of the expansion vessel is correct.
  • R
    rebeccaalvarezSep 2, 2025
    What to do if Daikin ERGA08DAV3A is not heating or cooling and water volume is low?
    • D
      Dale MillerSep 2, 2025
      If your Daikin Heat Pump isn't heating or cooling as expected, the water volume in the installation might be too low. Make sure that the water volume in the installation is above the minimum required value.
  • K
    Kim PrattSep 4, 2025
    Why does the pressure relief valve keep opening on my Daikin ERGA08DAV3A Heat Pump?
    • J
      Justin AndersonSep 4, 2025
      If the pressure relief valve of your Daikin Heat Pump opens, it could be due to several reasons: * The expansion vessel might be broken. Replace it. * The valve of the water circuit towards the expansion vessel might be closed. Open the valve. * The water volume in the installation might be too high. Ensure it is below the maximum allowed value. * The water circuit head might be too high. Check the installation requirements.
  • C
    Charles DunnSep 7, 2025
    What to do if preferential kWh rate signal was sent by the electricity company and Daikin Heat Pump compressor does not start?
    • J
      Jason MccannSep 7, 2025
      If the compressor in your Daikin Heat Pump isn't starting for space heating or domestic water heating, it could be because the preferential kWh rate signal was sent by the electricity company. Wait for the power to return (2 hours max.).
  • T
    tamaranicholsSep 9, 2025
    Why is the water pressure unusually high at the tapping point of my Daikin ERGA08DAV3A Heat Pump?
    • E
      ebaileySep 9, 2025
      If the pressure at the tapping point of your Daikin Heat Pump is temporarily unusually high, it could be due to a failing or blocked pressure relief valve. Flush and clean the complete tank, including the piping between the pressure relief valve and the cold water inlet, or replace the pressure relief valve.

Summary

General Safety Precautions

For the Installer

Provides essential safety guidelines and precautions specifically for installers.

Units and Options

Application Guidelines

Space Heating;Cooling System Setup

Guides on configuring the system for various space heating and cooling setups.

Auxiliary Heat Source for Space Heating

Explains how to integrate and configure an auxiliary boiler for space heating.

Domestic Hot Water Tank Setup

Covers system layout, DHW consumption, and tank setup for domestic hot water.

Power Consumption Control Setup

Explains how to set up power limitation for the entire system.

Preparation

Installation Site Preparation

Details requirements and considerations for preparing the installation site.

Refrigerant Piping Preparation

Covers requirements for refrigerant piping material, diameter, and insulation.

Water Piping Preparation

Covers water circuit requirements, piping diameter, flow rate, and pressure.

Electrical Wiring Preparation

Covers general precautions and requirements for electrical wiring.

Installation

Mounting the Outdoor Unit

Guides on the process of mounting the outdoor unit, including structure and precautions.

Mounting the Indoor Unit

Guides on the process of mounting the indoor unit and its precautions.

Connecting Refrigerant Piping

Covers all aspects of connecting refrigerant piping, including precautions and guidelines.

Checking Refrigerant Piping

Covers leak checking and vacuum drying procedures for refrigerant piping.

Charging Refrigerant

Covers the process of charging refrigerant, including additional and complete recharging.

Connecting Water Piping

Covers connecting water piping, including recirculation and drain hoses.

Connecting Electrical Wiring

Covers all steps and precautions for connecting electrical wiring to the unit.

Configuration

Configuration Wizard

Guides users through the initial system configuration using the wizard.

Commissioning

Checklist before Commissioning

Provides a checklist of items to verify before starting the commissioning process.

Checklist during Commissioning

Outlines checks and procedures to be performed during the commissioning process.

Hand-over to the User

Hand-over to the User

Outlines the steps for handing over the system to the user after successful installation and testing.

Maintenance and Service

Checklist for Yearly Maintenance of the Outdoor Unit

Provides a checklist for essential yearly maintenance tasks on the outdoor unit.

Checklist for Yearly Maintenance of the Indoor Unit

Provides a checklist for essential yearly maintenance tasks on the indoor unit.

Troubleshooting

Solving Problems Based on Symptoms

Offers solutions for common symptoms encountered with the unit's operation.

Solving Problems Based on Error Codes

Provides an overview of error codes and how to display detailed help text.

Field Settings Table