Installer reference guide
Daikin Altherma 3 R F
ERGA04DAV3(A)
ERGA06DAV3(A)
ERGA08DAV3(A)
EHVH04S18D*6V7
EHVH04S23D*6V7
EHVH08S18D*6V7
EHVH08S23D*6V7
EHVH08S18D*9W7
EHVH08S23D*9W7
EHVX04S18D*3V7
EHVX04S18D*6V7
EHVX04S23D*3V7
EHVX04S23D*6V7
EHVX08S18D*6V7
EHVX08S23D*6V7
EHVX08S18D*9W7
EHVX08S23D*9W7

Table of Contents

Questions and Answers

  • M
    Michael MosleyAug 17, 2025
    Why is my Daikin ERGA04DAV3A not sufficiently heating at low outdoor temperatures?
    • A
      Antonio BrownAug 18, 2025
      If your Daikin Heat Pump isn't sufficiently heating the space at low outdoor temperatures, it could be due to several reasons: * The backup heater operation might not be activated. Ensure the backup heater operation mode is enabled. * The backup heater overcurrent circuit breaker might be off. Turn it back on if it is off. * The thermal protector of the backup heater might be activated. If it has, check the water pressure, whether there is air in the system, and the air purge operation, then press the reset button in the switch box. * The backup heater equilibrium temperature may not be configured correctly. Try increasing the equilibrium temperature to activate the backup heater operation at a higher outdoor temperature.
  • K
    Kimberly ClarkAug 20, 2025
    How to check temperature settings on Daikin Heat Pump when it is not heating or cooling?
    • W
      William RamirezAug 20, 2025
      If your Daikin Heat Pump isn't heating or cooling as expected, first check the temperature setting on the remote controller to ensure it's correct. The issue might stem from an incorrect setting.
  • T
    Theodore CobbAug 22, 2025
    What to do if Daikin ERGA04DAV3A Heat Pump is not heating or cooling and water flow is low?
    • G
      Gloria SmithAug 22, 2025
      If your Daikin Heat Pump isn't heating or cooling as expected, it might be due to low water flow. Ensure all shut-off valves of the water circuit are completely open, the water filter is clean, and there is no air in the system. Also, check that the water pressure is above 1 bar, the expansion vessel is not broken, and the valve towards the expansion vessel is open. Verify that the resistance in the water circuit isn't too high for the pump.
  • M
    Madison BennettAug 25, 2025
    Why won't the compressor start on my Daikin ERGA04DAV3A Heat Pump for space or water heating?
    • M
      Mackenzie FoxAug 26, 2025
      If the compressor in your Daikin Heat Pump isn't starting for space or domestic water heating, it could be because the unit is starting outside of its operation range, meaning the water temperature is too low. In this case, the unit uses the backup heater to reach the minimum water temperature first (15°C). Check that the power supply to the backup heater is correctly wired, and the backup heater thermal protector is not activated, and the backup heater contactors are not broken.
  • W
    William SnyderAug 27, 2025
    Why is my Daikin ERGA04DAV3A Heat Pump system making gurgling noises?
    • S
      Stephen HuertaAug 27, 2025
      If your Daikin Heat Pump system is making gurgling noises after commissioning, it could be caused by air in the system. Purge the air from the system. It can also be caused by various malfunctions. Check if or is displayed on the home screen of the user interface for more information about the malfunction.
  • J
    Jacob MuellerAug 30, 2025
    How to fix a noisy pump (cavitation) in my Daikin ERGA04DAV3A Heat Pump?
    • P
      Pamela LambAug 30, 2025
      If the pump in your Daikin Heat Pump is making noise (cavitation), it could be due to air in the system. Purge the air manually or use the automatic air purge function. Another possible cause is that the water pressure at the pump inlet is too low. Ensure the water pressure is above 1 bar, the water pressure sensor is not broken, the expansion vessel is not broken, the valve of the water circuit towards the expansion vessel is open, and the pre-pressure setting of the expansion vessel is correct.
  • L
    lauraconnerSep 1, 2025
    What to do if Daikin ERGA04DAV3A is not heating or cooling and water volume is low?
    • S
      Sarah SullivanSep 2, 2025
      If your Daikin Heat Pump isn't heating or cooling as expected, the water volume in the installation might be too low. Make sure that the water volume in the installation is above the minimum required value.
  • D
    Derek GonzalesSep 4, 2025
    Why does the pressure relief valve keep opening on my Daikin Heat Pump?
    • S
      Seth GreenSep 4, 2025
      If the pressure relief valve of your Daikin Heat Pump opens, it could be due to several reasons: * The expansion vessel might be broken. Replace it. * The valve of the water circuit towards the expansion vessel might be closed. Open the valve. * The water volume in the installation might be too high. Ensure it is below the maximum allowed value. * The water circuit head might be too high. Check the installation requirements.
  • K
    Kelly PierceSep 6, 2025
    What to do if preferential kWh rate signal was sent by the electricity company and Daikin ERGA04DAV3A Heat Pump compressor does not start?
    • S
      Stephen GrantSep 6, 2025
      If the compressor in your Daikin Heat Pump isn't starting for space heating or domestic water heating, it could be because the preferential kWh rate signal was sent by the electricity company. Wait for the power to return (2 hours max.).
  • D
    Danny WilkersonSep 9, 2025
    Why is the water pressure unusually high at the tapping point of my Daikin Heat Pump?
    • R
      Regina HayesSep 9, 2025
      If the pressure at the tapping point of your Daikin Heat Pump is temporarily unusually high, it could be due to a failing or blocked pressure relief valve. Flush and clean the complete tank, including the piping between the pressure relief valve and the cold water inlet, or replace the pressure relief valve.

Summary

1 General safety precautions

1.2 For the installer

Covers general installation, site requirements, refrigerant, brine, water, and electrical safety precautions for installers.

5 Application guidelines

5.2 Setting up the space heating;cooling system

Guides setting up space heating/cooling for single and multiple rooms with various heat emitters.

5.4 Setting up the domestic hot water tank

Covers DHW tank setup, consumption calculation, volume selection, and pump configurations.

6 Preparation

6.2 Preparing the installation site

Covers site requirements for outdoor and indoor units, including spacing, environmental factors, and cold climates.

6.3 Preparing refrigerant piping

Details refrigerant piping specifications, including material, diameter, thickness, and insulation requirements.

6.4 Preparing water piping

Covers water circuit requirements, including piping standards, pressure, flow rate, and components.

6.5 Preparing electrical wiring

Provides guidelines for electrical wiring, safety precautions, and compliance with regulations.

7 Installation

7.3 Mounting the outdoor unit

Covers mounting the outdoor unit, including installation structures, precautions, and site requirements.

7.4 Mounting the indoor unit

Details the process of mounting the indoor unit, including handling, positioning, and drain connection.

7.5 Connecting the refrigerant piping

Provides detailed steps for connecting refrigerant piping, including bending, flaring, brazing, and valve usage.

7.6 Checking the refrigerant piping

Explains how to check for leaks and perform vacuum drying on the refrigerant piping.

7.7 Charging refrigerant

Guides on charging additional refrigerant and completely recharging the system, including label requirements.

7.8 Connecting water piping

Covers connecting water piping, including shut-off valves, bypass valve, and filling procedures.

7.9 Connecting the electrical wiring

Details electrical wiring connections for power supply, meters, pumps, alarms, and other system components.

8 Configuration

8.5 Settings menu

Covers various settings including malfunctioning, room, main zone, additional zone, tank, and user preferences.

9 Commissioning

9.4 Checklist during commissioning

Key checks and procedures to perform during the commissioning phase, including flow rate, air purge, and test runs.

10 Hand-over to the user

11 Maintenance and service

12 Troubleshooting

12.3 Solving problems based on symptoms

Provides solutions for common issues based on observable symptoms like lack of heating or unusual noises.

12.4 Solving problems based on error codes

Explains how to interpret system error codes and find corresponding solutions for malfunctions.

Daikin ERGA04DAV3A Specifications

General IconGeneral
BrandDaikin
ModelERGA04DAV3A
CategoryHeat Pump
LanguageEnglish