6 | Application guidelines
Installer reference guide
44
ERLA11~16D + EBVH16SU23D
Daikin Altherma 3 R F
4P655196-1A – 2022.05
Combination: Underfloor heating + Heatpump convectors – Multiple rooms
Setup
A
B C
a
b
M1
M1
A Main leaving water temperature zone
B Room 1
C Room 2
a External room thermostat
b Heatpump convectors (+ controllers)
▪ For more information about connecting the electrical wiring to the unit, see:
- "9.2Connections to the outdoor unit"[4123]
- "9.3Connections to the indoor unit"[4126]
▪ For each room with heat pump convectors: The heat pump convectors are
directly connected to the indoor unit.
▪ For each room with underfloor heating: Two shut-off valves (field supply) are
installed before the underfloor heating:
- A shut-off valve to prevent hot water supply when the room has no heating
demand
- A shut-off valve to prevent condensation on the floor during cooling operation
of the rooms with heatpump convectors.
▪ For each room with heat pump convectors: The desired room temperature is set
via the controller of the heat pump convectors. There are different controllers
and setups possible for the heat pump convectors. For more information, see:
- The installation manual of the heat pump convectors
- The installation manual of the heat pump convector options
- The addendum book for optional equipment
▪ For each room with underfloor heating: The desired room temperature is set via
the external room thermostat (wired or wireless).
▪ The user interface integrated in the indoor unit decides the space operation
mode. Mind that the operation mode on each external room thermostat and
controller of the heatpump convectors must be set to match the indoor unit.
INFORMATION
To increase comfort and performance, we recommend to install the valve kit option
EKVKHPC on each heatpump convector.