INSTALLATION AND
OPERATION MANUAL
EWAQ016BAW
EWAQ021BAW
EWAQ025BAW
EWAQ032BAW
EWAQ040BAW
EWAQ050BAW
EWAQ064BAW
EWYQ016BAW
EWYQ021BAW
EWYQ025BAW
EWYQ032BAW
EWYQ040BAW
EWYQ050BAW
EWYQ064BAW
Packaged air-cooled water chiller
4PWEN70082-1C.book Page 1 Wednesday, September 25, 2013 7:31 AM

Table of Contents

Other manuals for Daikin EWAQ040BAW

Questions and Answers:

Daikin EWAQ040BAW Specifications

General IconGeneral
BrandDaikin
ModelEWAQ040BAW
CategoryChiller
LanguageEnglish

Summary

2. PRECAUTIONS FOR INSTALLATION

Electrical and Temperature Safety Warnings

Emphasizes switching off power, avoiding hot parts, and managing alarm settings for safe operation.

3. PREPARATION FOR INSTALLATION

3.2. Verify Installation Location

Discusses site selection, animal deterrence, public access restrictions, environmental factors, and cold climate considerations.

3.6. Prepare Electrical Wiring

4. INSTALL THE CHILLER

4.5. Perform Water Piping Work

4.5.1. Connecting Water Pipes

Details precautions for connecting water pipes, including material compatibility, thread sealant, and flow regulation.

4.5.4. Check Water Volume and Expansion Vessel Pre-pressure

4.5.5. Protect Water Circuit Against Freezing

Use of Glycol

4.5.6. Fill Water Circuit

4.6. Connect Electrical Wiring

4.6.4. System Overview of Field Wiring

4.6.5. Connect Power Supply and Communication Cables

4.6.7. Install Remote Controller

5. COMMISSIONING THE CHILLER

5.1. Verify Completion of Installation

Lists essential checks before powering up the unit, including wiring, earth connection, and component integrity.

5.2. Configure the Unit

5.2.1. Final Air Purging

Explains using field setting [E-04] for pump-only operation to effectively remove air from the water circuit.

5.2.3. Field Settings on the Remote Controller

5.2.4. Procedure

[3] Weather Dependent Set Point

[3-02] Set Point at Low Ambient Temperature (Lo_Ti)

Specifies the target water temperature at low ambient conditions for optimal heating performance.

[3-03] Set Point at High Ambient Temperature (Hi_Ti)

Specifies the target water temperature at high ambient conditions for efficient cooling/heating.

[8-04] Freeze-up Prevention

[9] Automatic Temperature Compensation

[C] Leaving Water Temperature Limits

[E-04] Pump Only Operation (Air Purge Function)

5.3. Final Check and Test Run

5.3.1. Final Check

Lists essential checks before unit startup, including panel closure, electrical safety, and component integrity.

5.3.2. Unit Test Run

Outlines procedures for performing unit test runs for heating/cooling operations and verifying performance.

5.4. Handover to the User

2. GENERAL SAFETY PRECAUTIONS

4. QUICK START-UP OF THE UNIT

4.1. Space Cooling/Heating Operation

Provides a step-by-step guide for initial setup of space cooling and heating operations.

5. OPERATING THE UNIT

5.1. Operating the Remote Controller

Explains the remote controller's role in full control of the installation, including basic functions and features.

5.2. Name and Function of Buttons and Icons

7. MAINTENANCE AND TROUBLESHOOTING

8.1. Error Codes

Lists error codes, their causes, and corrective actions for diagnosing and resolving unit issues.

6. FIELD SETTINGS

6.1. Procedure

Provides a step-by-step guide for accessing and changing field settings using the remote controller.

6.1.1. Field Settings Table

6.1.1. Field Settings Table (Continued)