34
Performance Data
Model: FCRN71EXV1 - RR71CXV1
Cooling Mode
AFR
(CFM)
EWB EDB
Outdoor temperature
19°C 25°C 30°C 35°C 40°C 46°C
TC SC PI TC SC PI TC SC PI TC SC PI TC SC PI TC SC PI
620
16°C
21°C 7.46 5.49 2.12 7.19 5.34 2.29 6.93 5.20 2.48 6.65 5.05 2.69 6.10 4.70 2.92 5.64 4.42 3.22
24°C 7.47 6.57 2.12 7.20 6.42 2.29 6.94 6.27 2.48 6.66 6.11 2.69 6.12 5.71 2.92 5.66 5.39 3.22
27°C 7.53 7.45 2.12 7.28 7.28 2.30 7.02 7.02 2.49 6.76 6.76 2.70 6.23 6.23 2.93 5.80 5.80 3.23
30°C 7.76 7.76 2.13 7.54 7.54 2.31 7.31 7.31 2.51 7.07 7.07 2.72 6.55 6.55 2.96 6.13 6.13 3.26
19°C
24°C 8.23 5.12 2.15 7.94 4.99 2.33 7.65 4.86 2.53 7.34 4.72 2.74 6.75 4.40 2.97 6.24 4.14 3.28
27°C 8.23 5.86 2.15 7.94 5.73 2.33 7.65 5.60 2.53 7.35 5.46 2.74 6.76 5.11 2.97 6.25 4.84 3.28
30°C 8.24 7.23 2.15 7.96 7.08 2.33 7.68 6.92 2.53 7.39 6.76 2.74 6.80 6.32 2.98 6.31 5.98 3.28
33°C 8.34 8.34 2.16 8.07 8.07 2.34 7.81 7.81 2.54 7.54 7.54 2.75 6.98 6.98 2.99 6.52 6.52 3.30
22°C
27°C 9.05 5.01 2.19 8.74 4.89 2.38 8.42 4.77 2.57 8.09 4.64 2.79 7.44 4.32 3.03 6.89 4.08 3.34
30°C 9.05 6.11 2.19 8.74 5.98 2.38 8.42 5.84 2.58 8.09 5.71 2.79 7.44 5.34 3.03 6.89 5.06 3.34
33°C 9.06 7.14 2.19 8.74 7.00 2.38 8.43 6.86 2.58 8.10 6.72 2.79 7.45 6.31 3.03 6.91 5.99 3.34
36°C 9.09 8.09 2.19 8.79 7.93 2.38 8.48 7.77 2.58 8.17 7.59 2.80 7.54 7.12 3.04 7.01 6.75 3.35
725
16°C
21°C 7.76 5.72 2.14 7.48 5.58 2.31 7.20 5.43 2.51 6.90 5.27 2.72 6.33 4.91 2.95 5.84 4.62 3.25
24°C 7.78 6.95 2.14 7.50 6.78 2.31 7.22 6.62 2.51 6.93 6.46 2.72 6.37 6.02 2.95 5.89 5.68 3.25
27°C 7.88 7.88 2.15 7.61 7.61 2.32 7.35 7.35 2.51 7.09 7.09 2.73 6.54 6.54 2.96 6.09 6.09 3.27
30°C 8.21 8.21 2.16 7.97 7.97 2.34 7.72 7.72 2.54 7.47 7.47 2.75 6.92 6.92 2.99 6.47 6.47 3.30
19°C
24°C 8.55 5.41 2.17 8.24 5.28 2.35 7.93 5.14 2.55 7.62 5.00 2.76 6.99 4.66 3.00 6.46 4.39 3.30
27°C 8.56 6.24 2.17 8.26 6.10 2.35 7.95 5.96 2.55 7.63 5.82 2.77 7.01 5.44 3.00 6.48 5.15 3.31
30°C 8.60 7.69 2.18 8.31 7.53 2.36 8.01 7.36 2.55 7.70 7.18 2.77 7.09 6.71 3.01 6.58 6.34 3.31
33°C 8.75 8.75 2.18 8.48 8.48 2.37 8.21 8.21 2.57 7.94 7.94 2.79 7.35 7.35 3.03 6.87 6.87 3.34
22°C
27°C 9.39 5.30 2.21 9.06 5.18 2.40 8.73 5.05 2.60 8.38 4.91 2.82 7.70 4.58 3.06 7.12 4.32 3.37
30°C 9.40 6.50 2.21 9.07 6.37 2.40 8.73 6.23 2.60 8.39 6.08 2.82 7.71 5.70 3.06 7.13 5.41 3.37
33°C 9.42 7.62 2.22 9.09 7.48 2.40 8.76 7.32 2.60 8.42 7.17 2.82 7.74 6.72 3.06 7.18 6.38 3.37
36°C 9.48 8.62 2.22 9.17 8.45 2.41 8.85 8.28 2.61 8.53 8.09 2.83 7.87 7.57 3.07 7.34 7.14 3.39
860
16°C
21°C 8.05 5.97 2.16 7.75 5.82 2.33 7.45 5.67 2.53 7.15 5.51 2.74 6.55 5.13 2.97 6.04 4.83 3.27
24°C 8.09 7.26 2.16 7.80 7.09 2.33 7.50 6.91 2.53 7.20 6.73 2.74 6.61 6.28 2.97 6.11 5.92 3.28
27°C 8.22 8.22 2.17 7.95 7.95 2.34 7.68 7.68 2.54 7.41 7.41 2.76 6.84 6.84 2.99 6.38 6.38 3.30
30°C 8.63 8.63 2.18 8.38 8.38 2.37 8.12 8.12 2.57 7.85 7.85 2.79 7.27 7.27 3.03 6.79 6.79 3.34
19°C
24°C 8.86 5.73 2.19 8.54 5.59 2.37 8.21 5.44 2.57 7.88 5.30 2.79 7.23 4.94 3.02 6.67 4.66 3.33
27°C 8.88 6.63 2.19 8.56 6.48 2.37 8.24 6.32 2.57 7.91 6.17 2.79 7.26 5.77 3.03 6.71 5.46 3.33
30°C 8.96 8.16 2.20 8.64 7.98 2.38 8.33 7.80 2.58 8.01 7.60 2.80 7.38 7.10 3.03 6.85 6.69 3.35
33°C 9.15 9.15 2.21 8.88 8.88 2.39 8.61 8.61 2.60 8.33 8.33 2.82 7.71 7.71 3.06 7.21 7.21 3.38
22°C
27°C 9.72 5.60 2.23 9.37 5.48 2.42 9.02 5.34 2.62 8.66 5.20 2.84 7.95 4.86 3.08 7.35 4.58 3.39
30°C 9.74 6.91 2.23 9.39 6.78 2.42 9.04 6.63 2.62 8.68 6.48 2.84 7.97 6.07 3.08 7.37 5.75 3.40
33°C 9.77 8.10 2.24 9.44 7.96 2.42 9.09 7.79 2.63 8.73 7.62 2.85 8.03 7.14 3.09 7.44 6.77 3.40
36°C 9.86 9.14 2.24 9.55 8.98 2.43 9.22 8.78 2.64 8.89 8.56 2.86 8.21 7.99 3.11 7.66 7.52 3.43
Remark:
AFR: Air ow rate (CFM)
EWB: Entering Wet Bulb Temp. (°C)
EDB: Entering Dry Bulb Temp. (°C)
TC: Total Cooling Capacity (kW)
SC: Sensible Cooling Capacity (kW)
PI: Power Input (kW)
Notes:
1. Ratings shown are net capacities.
2. shows nominal capacities.
3. Direct interpolation is permissible. Do not extrapolate.
4. Unit is able to operate at ambient from 19°C to 46°C DB without pressure trip.
DAIKIN_FFRN.indb 34DAIKIN_FFRN.indb 34 12/27/2012 9:28:12 AM12/27/2012 9:28:12 AM