Performance Data
Model: FCQN100EXV1- RQ90DXV1
Cooling Mode
AFR
(CFM)
EWB EDB
Outdoor temperature
19°C 25°C 30°C 35°C 40°C 46°C
TC SC PI TC SC PI TC SC PI TC SC PI TC SC PI TC SC PI
740
16°C
21°C 8.07 6.17 2.14 7.78 6.00 2.32 7.50 5.84 2.51 7.19 5.68 2.72 6.61 5.28 2.95 6.10 4.97 3.25
24°C 8.08 7.38 2.14 7.79 7.21 2.32 7.51 7.05 2.51 7.21 6.87 2.72 6.62 6.42 2.95 6.12 6.05 3.26
27°C 8.14 8.14 2.15 7.87 7.87 2.32 7.60 7.60 2.52 7.31 7.31 2.73 6.75 6.75 2.96 6.28 6.28 3.27
30°C 8.40 8.40 2.16 8.15 8.15 2.34 7.91 7.91 2.53 7.65 7.65 2.75 7.09 7.09 2.99 6.64 6.64 3.30
19°C
24°C 8.90 5.76 2.18 8.59 5.61 2.36 8.27 5.46 2.55 7.95 5.31 2.77 7.30 4.94 3.00 6.75 4.65 3.31
27°C 8.91 6.59 2.18 8.59 6.44 2.36 8.28 6.29 2.55 7.95 6.14 2.77 7.31 5.74 3.00 6.76 5.44 3.31
30°C 8.92 8.13 2.18 8.61 7.95 2.36 8.31 7.78 2.56 7.99 7.59 2.77 7.36 7.10 3.01 6.83 6.72 3.32
33°C 9.03 9.03 2.18 8.73 8.73 2.36 8.45 8.45 2.56 8.16 8.16 2.78 7.55 7.55 3.02 7.06 7.06 3.34
22°C
27°C 9.79 5.63 2.22 9.45 5.50 2.40 9.11 5.36 2.60 8.75 5.21 2.82 8.05 4.86 3.06 7.45 4.58 3.37
30°C 9.80 6.87 2.22 9.46 6.72 2.40 9.11 6.57 2.60 8.76 6.41 2.82 8.05 6.00 3.06 7.45 5.69 3.37
33°C 9.80 8.02 2.22 9.46 7.87 2.40 9.12 7.71 2.60 8.76 7.55 2.82 8.06 7.09 3.06 7.47 6.73 3.38
36°C 9.83 9.09 2.22 9.51 8.91 2.40 9.18 8.73 2.61 8.84 8.53 2.83 8.16 8.00 3.07 7.58 7.58 3.39
860
16°C
21°C 8.40 6.43 2.16 8.09 6.26 2.34 7.79 6.10 2.53 7.47 5.93 2.75 6.85 5.52 2.98 6.32 5.19 3.28
24°C 8.42 7.81 2.16 8.12 7.62 2.34 7.82 7.44 2.53 7.50 7.25 2.75 6.89 6.77 2.98 6.37 6.37 3.29
27°C 8.52 8.52 2.17 8.24 8.24 2.35 7.95 7.95 2.54 7.67 7.67 2.76 7.08 7.08 2.99 6.59 6.59 3.30
30°C 8.88 8.88 2.18 8.62 8.62 2.36 8.36 8.36 2.56 8.09 8.09 2.78 7.49 7.49 3.03 7.00 7.00 3.34
19°C
24°C 9.25 6.08 2.20 8.92 5.93 2.38 8.59 5.78 2.58 8.24 5.62 2.79 7.57 5.23 3.03 6.99 4.93 3.34
27°C 9.27 7.01 2.20 8.94 6.85 2.38 8.60 6.70 2.58 8.26 6.54 2.80 7.59 6.11 3.03 7.01 5.79 3.34
30°C 9.31 8.64 2.20 8.99 8.46 2.38 8.67 8.27 2.58 8.33 8.07 2.80 7.67 7.54 3.04 7.12 7.12 3.35
33°C 9.47 9.47 2.21 9.18 9.18 2.39 8.89 8.89 2.60 8.59 8.59 2.82 7.96 7.96 3.06 7.44 7.44 3.38
22°C
27°C 10.16 5.96 2.24 9.81 5.82 2.42 9.44 5.67 2.63 9.07 5.52 2.85 8.33 5.15 3.09 7.71 4.85 3.40
30°C 10.18 7.31 2.24 9.82 7.16 2.42 9.45 7.00 2.63 9.08 6.84 2.85 8.34 6.40 3.09 7.72 6.07 3.41
33°C 10.20 8.57 2.24 9.84 8.40 2.43 9.48 8.23 2.63 9.11 8.05 2.85 8.38 7.56 3.10 7.77 7.17 3.41
36°C 10.26 9.68 2.24 9.93 9.50 2.43 9.58 9.30 2.64 9.23 9.08 2.86 8.52 8.50 3.11 7.94 7.94 3.43
1030
16°C
21°C 8.71 6.71 2.18 8.39 6.54 2.36 8.07 6.37 2.55 7.73 6.19 2.77 7.09 5.77 3.00 6.54 5.43 3.31
24°C 8.75 8.15 2.18 8.44 7.96 2.36 8.12 7.77 2.56 7.79 7.56 2.77 7.16 7.06 3.01 6.61 6.61 3.31
27°C 8.90 8.90 2.19 8.60 8.60 2.37 8.31 8.31 2.57 8.02 8.02 2.79 7.41 7.41 3.02 6.90 6.90 3.34
30°C 9.34 9.34 2.21 9.07 9.07 2.39 8.79 8.79 2.59 8.50 8.50 2.82 7.87 7.87 3.06 7.35 7.35 3.38
19°C
24°C 9.59 6.44 2.22 9.24 6.28 2.40 8.89 6.12 2.60 8.53 5.95 2.82 7.82 5.55 3.06 7.22 5.23 3.37
27°C 9.61 7.45 2.22 9.27 7.28 2.40 8.92 7.11 2.60 8.56 6.93 2.82 7.86 6.48 3.06 7.26 6.13 3.37
30°C 9.69 9.17 2.22 9.35 8.97 2.41 9.01 8.76 2.61 8.67 8.54 2.83 7.98 7.98 3.07 7.41 7.41 3.38
33°C 9.90 9.90 2.23 9.61 9.61 2.42 9.32 9.32 2.62 9.01 9.01 2.85 8.35 8.35 3.10 7.81 7.81 3.42
22°C
27°C 10.52 6.30 2.26 10.14 6.16 2.45 9.76 6.00 2.65 9.37 5.85 2.87 8.61 5.46 3.12 7.95 5.15 3.43
30°C 10.54 7.76 2.26 10.16 7.62 2.45 9.78 7.45 2.65 9.39 7.28 2.88 8.63 6.82 3.12 7.98 6.46 3.43
33°C 10.58 9.10 2.26 10.21 8.94 2.45 9.84 8.75 2.66 9.45 8.56 2.88 8.69 8.02 3.12 8.05 7.61 3.44
36°C 10.67 10.27 2.27 10.34 10.09 2.46 9.98 9.86 2.66 9.62 9.62 2.89 8.89 8.89 3.14 8.29 8.29 3.46
Model: FCQN100EXV1- RQ90DXV1
Heating Mode
ID DB
Outdoor WB
-9°C -6°C -5°C 6°C 12°C 15°C 18°C
TC SC TC SC TC SC TC SC TC SC TC SC TC SC
15°C
5.527 5.527 6.256 6.256 6.499 6.499 9.171 9.171 10.628 10.628 11.357 11.357 12.085 12.085
17°C
5.382 5.382 5.751 5.751 6.382 6.382 9.160 9.160 10.633 10.633 11.383 11.383 12.133 12.133
19°C
5.238 5.238 5.247 5.247 6.266 6.266 9.149 9.149 10.637 10.637 11.409 11.409 12.180 12.180
21°C
5.093 5.093 5.069 5.069 6.150 6.150 9.115 9.115 10.642 10.642 11.435 11.435 12.228 12.228
23°C
4.948 4.948 5.217 5.217 6.033 6.033 9.057 9.057 10.647 10.647 11.461 11.461 12.275 12.275
25°C
4.803 4.803 5.366 5.366 5.917 5.917 9.000 9.000 10.652 10.652 11.487 11.487 12.323 12.323
27°C
4.658 4.658 5.515 5.515 5.800 5.800 8.942 8.942 10.656 10.656 11.513 11.513 12.370 12.370
Frost Region
Remark:
AFR: Air ow rate (CFM)
EWB: Entering Wet Bulb Temp. (°C)
EDB: Entering Dry Bulb Temp. (°C)
TC: Total Cooling / Heating Capacity (kW)
SC: Sensible Cooling / Heating Capacity (kW)
PI: Power Input (kW)
Notes:
1. Ratings shown are net capacities.
2. shows nominal capacities.
3. Direct interpolation is permissible. Do not extrapolate.
4. Unit is able to operate at ambient from 19°C to 46°C DB (cooling) / -9°C to 18°C WB (heating) without pressure trip.