EasyManuals Logo

Daikin FDMQ18WVJU9 User Manual

Daikin FDMQ18WVJU9
303 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #186 background imageLoading...
Page #186 background image
Troubleshooting for Duct Concealed/Ceiling Cassette Type SiUS122226E
180 Part 6 Service Diagnosis
6.9 Signal Transmission Error (Between Indoor and Outdoor
Unit)
Error Code U4
Method of Error
Detection
The signal transmission data from the outdoor unit is checked whether it is normal.
Error Decision
Conditions
The data sent from the outdoor unit cannot be received normally, or the content of the data is
abnormal.
Supposed
Causes
Power supply voltage out of specification
Reduction of power supply voltage
Wiring error
Breaking of the connection wires between the indoor and outdoor units (wire No. 3)
Defective outdoor unit PCB
Short circuit inside the fan motor winding
Defective indoor unit PCB
Disturbed power supply waveform

Table of Contents

Other manuals for Daikin FDMQ18WVJU9

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin FDMQ18WVJU9 and is the answer not in the manual?

Daikin FDMQ18WVJU9 Specifications

General IconGeneral
BrandDaikin
ModelFDMQ18WVJU9
CategoryAir Conditioner
LanguageEnglish

Related product manuals