English
INSTALLATION
MANUAL
Installation Manual
R410A Split Series
MODELS
FDMRN20AV1K RR20AV1K
FDMRN25AV1K RR25AV1K
FDMRN30AV1K RR30AV1K
FDMRN36AV1K RR36AV1K
FDMRN36AV1K RR36AY1K
FDMRN50AV1K9 RR50AY1K9
FDMRN60AV1K RR60AY1K
R410A SPLIT SERIES
IM-5CC(HA)-1115(9)-DAIKIN
Part No.: R08019044313J
FDMRN20AV1KU RR20AV1KU
RR20AV1KRE
FDMRN25AV1KU RR25AV1KU
RR25AV1KRE
FDMRN30AV1KU RR30AV1KU
RR30AV1KRE
FDMRN36AV1KU RR36AV1KU
FDMRN50AV1KU RR50AY1KU
FDMRN60AV1KU RR60AY1KU
CVR IM-5CC(HA)-1115(9)-DAIKIN-EN1 1CVR IM-5CC(HA)-1115(9)-DAIKIN-EN1 1 6/10/21 12:39:02 PM6/10/21 12:39:02 PM

Questions and Answers

  • D
    Daniel HendersonAug 10, 2025
    Why my Daikin Air Conditioner unit does not operate?
    • M
      Michelle BradyAug 10, 2025
      If your Daikin Air Conditioner isn't turning on, here's what to check: * **Power Supply:** Make sure there isn't a power failure and that the fuse is working correctly. Check the power supply. * **Power Plug:** Ensure the power plug is properly connected; reconnect it if necessary. * **Delay Timer:** Verify that your delay timer is set correctly.
  • T
    Tracey BeckerAug 17, 2025
    How to increase air flow in my Daikin FDMRN36AV1KU?
    • T
      Tracy DavidsonAug 17, 2025
      If the airflow from your Daikin Air Conditioner is too low, here are a few things to check: * **Air Filter:** A dirty air filter can restrict airflow. Clean or replace the air filter. * **Air Suction and Discharge:** Make sure that the air suction and discharge are not blocked. Clear any clogs. * **Temperature Setting:** If you're in auto-fan mode, the regulated temperature might be too low. Try increasing the regulated temperature.
  • C
    Cody MooreAug 25, 2025
    What to do if there is condensation on my Daikin Air Conditioner?
    • A
      amandafergusonAug 25, 2025
      If you're seeing condensation on the front air grille of your Daikin Air Conditioner's indoor unit, it could be due to a couple of reasons: * **High Humidity:** After long operation, air humidity can cause condensation. Try to reduce humidity levels. * **Low Temperature Setting:** If the set temperature is too low, it can cause condensation. Increase the temperature setting and operate the unit at high fan speed.
  • A
    Antonio AyalaSep 1, 2025
    How to get rid of bad odor from Daikin FDMRN36AV1KU Air Conditioner?
    • M
      Mr. Christian RamosSep 1, 2025
      If the air coming from your Daikin Air Conditioner has a bad odor, it might be due to odors from sources like cigarettes, smoke, or perfume that have stuck to the coil. To resolve this, clean the coil.

Summary

Safety Precautions

General Safety Guidelines

Essential safety guidelines and warnings for installation and operation of the air conditioner unit.

Indoor Unit Installation

Outdoor Unit Installation

Refrigerant Piping

Piping Works and Flaring

Electrical Connections

R410 A Unit Precautions

Vacuuming and Charging

Piping and Indoor Unit Vacuuming

Procedure for evacuating moisture and air from refrigerant piping and indoor unit.

Refrigerant Charging Operation

Steps for charging the correct amount of refrigerant into the system.

Scroll Compressor Charging Precautions

Service and Maintenance

Troubleshooting Common Faults

Specifications

Daikin FDMRN36AV1KU Specifications

General IconGeneral
BrandDaikin
ModelFDMRN36AV1KU
CategoryAir Conditioner
LanguageEnglish