SiBE121135 Field Settings
Trial Operation and Field Settings 417
FVXS Series
1) Remove the front grille.
2) Lift the sensor PCB fixing plate and remove the front shield plate.
3) Disconnect the connectors [S1] [S41] [S42].
4) Remove the electric box (1 screw).
5) Pull out the indoor heat exchanger thermistor.
6) Remove the shield plate (8 tabs).
7) Cut the address setting jumper JA on the indoor unit PCB.
Floor / Ceiling
Suspended Dual
Type
Cut the jumper JA on PCB.
Duct Connected
Type
Cut the jumper JA on PCB.
Connector [S42]
Connector [S41]
Connector [S1]
4) Remove the screw.
5) Indoor heat exchanger
thermistor
(3)
6) Shield plate
(R17290)
Sensor
PCB fixing
plate
JC
JA
JB
JA
EXIST
CUT
Address
1
2
(2)
Front shield
plate
ADDRESS JA
(R11732)
EXIST
CUT
1
2
1 23
ADDRESS
JA
(R10276)
ADDRESS : JA
EXIST
CUT
1
2
JB
JC