Indoor Unit SiBE05-513A
134 Removal Procedure
1.8 Removal of the Fan Rotor / Fan Motor
Procedure Warning Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step Procedure Points
1
Remove the three fan
rotor covers. (Securing
hooks are located at A
and B-section.)
The right illustration
shows the opposite
side.
2
Disconnect the two
connection wirings
located at the rear side
of the fan motor and
unclamp the harness
from the clip.