REMOVAL
PROCEDURE
SERVICE MANUAL
Indoor Unit
Inverter / Non-Inverter
Wall Mounted Type
1.5/2.0/2.5/3.5/4.2/5.0 kW Class
9000/12000/15000/18000 Btu/h Class
Si041551EB
Question and Answer IconNeed help?

Do you have a question about the Daikin FTKC35QVM4 and is the answer not in the manual?

Daikin FTKC35QVM4 Specifications

General IconGeneral
Cooling Capacity3.5 kW
Heating Capacity4.0 kW
RefrigerantR32
Power Supply220-240 V, 50 Hz
Weight (Outdoor Unit)30 kg
Noise Level (Outdoor Unit)48 dB(A)
TypeSplit Type

Summary

Air Filters and Front Panel Removal

Electrical Box Removal

Disconnect Connecting Wire and Remove Service Cover

Disconnect wire, remove screw, unfasten hook, remove wire fixture.

Remove Electrical Box and Earth Wire

Remove screw, detach earth/ground wire, release from front slit.

PCBs Removal

Control PCB - Connector & Harness Removal

Remove connector [S26] and release harnesses from hooks and slit.

Control PCB - Terminal & Wire Release

Disconnect terminals and release earth/ground wire from slit/groove.

Drain Pan, Swing Motors, and Vertical Blades

Indoor Heat Exchanger Removal

Disconnect Refrigerant Piping

Disconnect drain hose, flare nuts for gas and liquid piping.