34
English
When the Need Arises
Mist comes out
Case Description / what to check
Mist comes out of the indoor unit.
• ThishappenswhentheairintheroomiscooledintomistbythecoldairowduringCOOL
orotheroperation.
Remote controller
Case Description / what to check
The unit does not receive signals
from the remote controller or has
a limited operating range.
• Thebatteriesmaybeexhausted.
ReplacebothbatterieswithnewdrybatteriesAAA.LR03(alkaline).
Fordetails,referto“Preparation Before Operation”.
Page 9
• Signalcommunicationmaybedisabledifanelectronic-starter-typeuorescentlamp(such
asinverter-typelamps)isintheroom.Consultyourdealerifthatisthecase.
• Theremotecontrollermaynotfunctioncorrectlyifthetransmitterisexposedtodirect
sunlight.
LCD is faint, is not working, or the
display is erratic.
• Thebatteriesmaybeexhausted.
ReplacebothbatterieswithnewdrybatteriesAAA.LR03(alkaline).
Fordetails,referto“Preparation Before Operation”.
Page 9
Other electric devices start
operating.
• Iftheremotecontrolleractivatesotherelectricdevices,movethemawayorconsultyour
dealer.
Air has an odour
Case Description / what to check
The air conditioner gives off an
odour.
• Theroomodourabsorbedintheunitisdischargedwiththeairow.
Werecommendyoutohavetheindoorunitcleaned.Pleaseconsultyourdealer.
Others
Case Description / what to check
The air conditioner suddenly
starts behaving strangely during
operation.
• Theairconditionermaymalfunctionduetolightningorradio.
Iftheairconditionermalfunctions,turnoffthepowerwiththecircuitbreakerandrestartthe
operationwiththeremotecontroller.
HEAT operation cannot be
selected, even though the unit is
heat pump model.
• Checkthatthejumper(J8)hasnotbeencut.Ifit
hasbeencut,contactyourdealer.
Jumper (J8)
The ON/OFF TIMER does not
operate according to the settings.
• CheckiftheON/OFFTIMERandtheWEEKLYTIMERaresettothesametime.
ChangeordeactivatethesettingsintheWEEKLYTIMER.
Page 21
Notes on the operating conditions
•
Ifoperationcontinuesunderanyconditionsotherthanthoselistedinthetable,
−Asafetydevicemayactivatetostoptheoperation.
−DewmayformontheindoorunitanddripfromitwhenCOOLorDRY
operationisselected.
Mode Operating conditions
DRY
Outdoortemperature:10-52°C
Indoortemperature:18-32°C
Indoorhumidity:80%max.
COOL
Outdoortemperature:10-52°C
Indoortemperature:18-32°C
Indoorhumidity:80%max.
HEAT
Outdoortemperature:0-24°C
Indoortemperature:10-30°C