EasyManua.ls Logo

Daikin FTKS25BVMB - Service Check Function

Daikin FTKS25BVMB
201 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Service Check Function SiBE04-302
90 Service Diagnosis
3. Service Check Function
In the ARC433A series, the temperature display sections on the main unit indicate
corresponding codes.
1. When the timer cancel button is held down for 5 seconds, a 00 indication flashes on the
temperature display section.
2. Press the timer cancel button repeatedly until a continuous beep is produced.
The code indication changes in the sequence shown below, and notifies with a long beep.
Note: 1. A short beep and two consecutive beeps indicate non-corresponding codes.
2. To cancel the code display, hold the timer cancel button down for 5 seconds. The code
display also cancels itself if the button is not pressed for 1 minute.
No. Code No. Code No. Code
1 00 11 E7 21 UA
2 U4 12 C7 22 A5
3 F3 13 H8 23 J9
4 E6 14 J3 24 E8
5 L5 15 A3 25 P4
6 A6 16 A1 26 L3
7 E5 17 C4 27 L4
8 LC 18 C5 28 H6
9 C9 19 H9 29 H7
10 U0 20 J6 30 U2
<
ARC433A1, A2
>
(R3038)

Table of Contents

Other manuals for Daikin FTKS25BVMB