SiENBE12-713 Main Functions
Function and Control 69
1.8 Night Set Mode
When the OFF timer is set, the Night Set circuit automatically activates.
The Night Set circuit maintains the airflow setting made by users.
The Night Set
Circuit
The Night Set circuit continues heating or cooling the room at the set temperature for the first
one hour, then automatically raises the temperature setting slightly in the case of cooling, or
lowers it slightly in the case of heating, for economical operations. This prevents excessive
heating in winter and excessive cooling in summer to ensure comfortable sleeping conditions,
and also conserves electricity.
Cooling
Operation
In case of FTXG25-35E, CTXG50E, FTK(X)S20-50D, FVXS25-50F the temperature rises once.
Heating
Operation
0.5°C
0.5°C
1 hour
30 minutes
Operation stops
at the set hours
Temperature
setting +1°C
Temperature
setting +0,5°C
Temperature
setting
+0.5°C
temperature schift
When outside temperature is normal and
room temperature is at set temperature.
When outside temperature is high (27°C or higher).
+0.5°C temperature schift
Temperature setting remains the same
Timer operation
Night Set Circuit ON
(R1361)
(R4421)
0.5°C
+0.5°C
temperature schift
Temperature
setting +0.5°C
Temperature
setting
1 hour
Temperature stops
at the set hours
Timer operation
Night Set Circuit ON
Thermostat
setting
Timer operation
Night Set Circuit ON
1 hour later
2°C
(R1362)