Si041137 Removal of Horizontal Blades / Vertical Blades
Removal Procedure 9
2
Remove the fan guard.
4. Remove the vertical blade
ASSYs.
1
Detach the pivot from
the interlock shaft for
vertical blades with a
flat screwdriver.
2
Remove the interlock
rod.
3
Unfasten the hooks at
the upper 3 positions by
pressing them with a
flat screwdriver.
Step
Procedure Points
(R8079)
(R13092)
Vertical blade ASSY
Pivot
Interlock
shaft
(R13093)
Interlock rod
(R13094)