SiBE04-302 Specifications
Specifications 15
230V, 50Hz
Notes:
MAX. interunit piping length: 15m
MAX. interunit height difference: 15m
Amount of additional charge of refrigerant 20g/m for piping length exceeding 10m
The data are based on the conditions shown in the table below.
Models
Indoor Units FTS35BVMB
Outdoor Units RS35BVMB
Capacity
kW 3.15
Btu/h 10,750
kcal/h 2,710
Moisture Removal L/h 1.7
Running Current (Rated) A 6.0
Power Consumption (Rated) W 1,120
Power Factor % 81.2
COP (Rated) W/W 2.81
Piping
Connections
Liquid mm
φ
6.4
Gas mm
φ
9.5
Drain mm
φ
18.0
Heat Insulation Both Liquid and Gas Pipes
Indoor Unit FTS35BVMB
Front Panel Color White
Air Flow Rate
m³/min
(cfm)
H 8.0 (283)
M 6.3 (223)
L 4.5 (159)
Fan
Type Cross Flow Fan
Motor Output W 18
Speed Steps 5 Steps and Auto
Air Direction Control Right, Left, Horizontal and Downward
Air Filter Removable / Washable / Mildew Proof
Running Current (Rated) A 0.18
Power Consumption (Rated) W 40
Power Factor % 96.6
Temperature Control Microcomputer Control
Dimensions (H×W×D) mm 273×784×185
Packaged Dimensions (W×D×H) mm 834×325×258
Weight kg 7.5
Gross Weight kg 11
Operation
Sound
H/M/L dBA 39 / 33 / 27
Sound Power dBA H 55
Outdoor Unit RS35BVMB
Casing Color Ivory White
Compressor
Type Hermetically Sealed Swing Type
Model 1YC23KXA#A
Motor Output W 600
Refrigerant
Oil
Type FVC50K
Charge L 0.43
Refrigerant
Type R410A
Charge kg 0.96
Air Flow Rate
m³/min 27.5
cfm 972
Fan
Type Propeller
Motor Output W 25
Running Current (Rated) A 5.82
Power Consumption (Rated) W 1,080
Power Factor % 80.7
Starting Current A 6.0
Dimensions (H×W×D) mm 560×695×265
Packaged Dimensions (W×D×H) mm 797×310×599
Weight kg 37
Gross Weight kg 40
Operation Sound dBA 47
Sound Power dBA H 60
Drawing No. 3D039745A
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3414
cfm=m³/min×35.3
Cooling Piping Length
Indoor ; 27°CDB/19°CWB
Outdoor ; 35°CDB/24°CWB
7.5m