What to do if my Daikin FTKS35CAVMB Air Conditioner heating stops suddenly?
- LLisa WilliamsSep 4, 2025
The system is likely removing frost from the outdoor unit. You should wait for about 3 to 8 minutes.
What to do if my Daikin FTKS35CAVMB Air Conditioner heating stops suddenly?
The system is likely removing frost from the outdoor unit. You should wait for about 3 to 8 minutes.
Why does mist come out of my Daikin FTKS35CAVMB Air Conditioner?
This happens when the air in the room is cooled into mist by the cold air flow during cooling operation.
Why is the Daikin Air Conditioner outdoor fan running when it's off?
After operation is stopped, the outdoor fan may continue rotating for another 60 seconds for system protection. Also, when the outdoor temperature is very high, the outdoor fan might start rotating for system protection even when the air conditioner is not in operation.
What to do if my Daikin FTKS35CAVMB operation stopped suddenly?
For system protection, the air conditioner may stop operating due to a sudden large voltage fluctuation. It will automatically resume operation in about 3 minutes.
Why my Daikin Air Conditioner does not start immediately?
If the ON/OFF button was pressed soon after operation was stopped, or if the mode was reselected, you should wait for about 3 minutes.
What to do if Daikin Air Conditioner heating operation stops suddenly and a flowing sound is heard?
If the heating operation of your Daikin Air Conditioner stops suddenly and you hear a flowing sound, you should wait for about 3 to 8 minutes.
Why does mist come out of the Daikin Air Conditioner indoor unit?
This occurs when the air in the room is cooled into mist by the cold airflow during cooling operation of the Daikin Air Conditioner.
What to do if an abnormal functioning happens during Daikin FTKS35CAVMB operation?
If you experience abnormal functioning during Daikin Air Conditioner operation, turn the breaker OFF, then turn it ON again. After that, try operating the air conditioner using the remote controller.
Why doesn't hot air come out immediately from my Daikin FTKS35CAVMB Air Conditioner when heating?
You should wait for 1 to 4 minutes. The system is designed to start discharging air only after it has reached a certain temperature.
What to do if Daikin FTKS35CAVMB Air Conditioner operation stops suddenly and the OPERATION lamp flashes?
If the Daikin Air Conditioner operation stops suddenly and the OPERATION lamp flashes, clean the air filters or remove any obstructions. Then, turn the breaker OFF, turn it ON again, and try operating the air conditioner.
Details severe consequences of not following instructions.
Details consequences of not following instructions.
Covers fire, explosion, injury, and exposure to airflow.
Warnings about appliances, outlets, outdoor units, moisture, and children.
Advice on choosing installation locations based on environment.
Guidance on selecting installation sites to avoid neighbor annoyance.
Specifies the need for a dedicated power circuit.
Notes that relocation requires specialized knowledge.
Identifies and describes components of the indoor unit.
Identifies and describes components of the outdoor unit.
Detailed descriptions of indoor unit components like filters and sensors.
Explains the function of switches and lamps on the indoor unit.
Details of outdoor unit components like air inlet, outlet, and sensors.
Identifies and describes each button and display on the remote.
Step-by-step instructions for inserting batteries into the remote.
Guidance on battery types, replacement frequency, and lifespan.
Instructions on how to use the remote controller effectively.
Steps for installing the remote control holder on a wall.
Precautions for remote controller use, like sunlight and dust.
Procedure to set the current time on the remote controller.
Describes the normal procedure when turning the breaker on.
Recommendations for efficient energy use and temperature settings.
Details operating conditions for different modes and potential issues.
Steps to start the air conditioner using the remote.
Steps to stop the air conditioner using the remote.
How to adjust the temperature for cooling/heating/auto modes.
How to set the fan speed for different modes.
How to reduce indoor unit noise by adjusting airflow.
Explains specific notes for HEAT, COOL, DRY, and AUTO operations.
Explains the impact of air flow rate on cooling/heating effect.
Instructions for setting the horizontal flap direction.
How to manually adjust the vertical louvers.
Information on flap swing range and angles based on operation mode.
Warnings about adjusting flaps and louvers to avoid damage.
How to activate the POWERFUL operation mode.
How to deactivate the POWERFUL operation mode.
Details on how POWERFUL operation works in different modes.
How to activate the quiet operation for the outdoor unit.
How to deactivate the quiet operation for the outdoor unit.
Conditions and limitations for using the quiet operation feature.
How to activate the HOME LEAVE operation.
How to deactivate the HOME LEAVE operation.
Instructions to set preferred temperature and airflow for HOME LEAVE.
Examples of when HOME LEAVE operation is beneficial.
How to record and retrieve favorite settings with HOME LEAVE.
Important notes and limitations for using HOME LEAVE operation.
How to activate the INTELLIGENT EYE sensor function.
How to deactivate the INTELLIGENT EYE sensor function.
How to change the detection area of the INTELLIGENT EYE sensor.
How the INTELLIGENT EYE feature contributes to energy saving.
Details on application range and limitations of INTELLIGENT EYE.
Warnings regarding placement and handling of the INTELLIGENT EYE sensor.
Steps to set the unit to turn off automatically.
How to cancel a set OFF TIMER.
Automatic temperature adjustment for sleep comfort with OFF TIMER.
Steps to set the unit to turn on automatically.
How to cancel a set ON TIMER.
Example of setting both ON and OFF timers simultaneously.
When to reset timer settings after power interruptions.
How to select modes when no priority room is set in a multi-system.
Details on the NIGHT QUIET Mode for cooling operations in multi-systems.
How to use OUTDOOR UNIT QUIET operation with multi-systems.
Explanation of the mode lock feature for heat pump multi-systems.
How the priority room setting affects operation mode selection.
How priority room affects POWERFUL operation capacity distribution.
How priority room setting affects OUTDOOR UNIT QUIET operation.
General instructions for cleaning the indoor, outdoor units, and remote.
Detailed steps for opening, cleaning, and reattaching the front panel.
Safety warnings and precautions during cleaning operations.
Instructions on cleaning or replacing air filters and purifying filters.
How to wash or vacuum clean the air filters.
How to clean or replace the air purifying filter.
Items to check before operating the air conditioner.
Steps to prepare the unit for extended periods of non-use.
Information regarding dirty filters and ordering replacement parts.
Explains normal operational behaviors that might seem like issues.
Explains causes and solutions for common operational problems.
Checks to perform before calling a repair person.
Troubleshooting steps when the operation lamp flashes.
Actions to take for malfunctions caused by lightning or radio waves.
Critical warnings and actions for abnormal situations.
List of symptoms that indicate a need for professional service.
Guidelines for environmentally sound disposal of the product.
How to access fault codes using the remote controller.
Table of error codes and their corresponding meanings.
Explains LED status on the outdoor unit PCB for fault diagnosis.
Explains LED status on the outdoor unit PCB for fault diagnosis.
Important notes regarding LED display interpretation and potential PCB faults.