Outdoor Unit SiENBE04-507A
184 Removal Procedure
2. Remove the panels.
1
Loosen the 3 screws
(front, right, left) and lift
the top panel.
2
Remove the drip proof
plate.
3
Disconnect the
connector for fan motor
(S70).
The fan motor is united with
the front panel.
4
Loosen the 5 screws of
the front panel.
Step
Procedure Points
Top panel
Drip proof plate
S70
Front panel