Daikin FTKS60FV1B - Radiation Fin Temperature Rise

Daikin FTKS60FV1B
355 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SiENBE12-713 Troubleshooting
Service Diagnosis 267
5.23 Radiation Fin Temperature Rise
Remote Control
Display
L4
Outdoor Unit LED
Display
A 5 1 1 2 1 3 1 4 4
Method of
Malfunction
Detection
A radiation fin temperature rise is detected by checking the radiation fin temperature being
detected by the fin thermistor with the compressor on.
Malfunction
Decision
Conditions
" The radiation fin temperature with the compressor on is above 103°C.
" The error is cleared when the temperature drops below 95°C.
" If a radiation fin temperature rise takes place 255 times successively, the system will be shut
down.
" The error counter will reset itself if this or any other error does not occur during the following
60-minute compressor running time (total time).
Supposed
Causes
" Fin temperature rise due to defective outdoor unit fan
" Fin temperature rise due to short-circuit
" Fin thermistor defective
" Connector in poor contact
" Outdoor unit PCB defective