EasyManuals Logo

Daikin FTKS71HVM User Manual

Daikin FTKS71HVM
33 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #9 background imageLoading...
Page #9 background image
Si041352ED Electrical Box
Removal Procedure 7
4 Pull out the indoor heat
exchanger thermistor.
The position of the indoor
heat exchanger thermistor
varies depending on the
model.
Some models have a clamp
fixing the indoor heat
exchanger thermistor to the
indoor heat exchanger.
Cut the clamp, if any.
Be careful not to lose the clip
of the thermistor.
5
6
Remove the screw, and
then the wire fixture.
Remove the 4 screws
on the terminal strip
and disconnect the
connecting wire.
7 Disconnect the
connector [S1] and
release the harness
from the hook.
[S1]: fan motor
For U.S. models
When reassembling, make
sure that the connecting wire
is passed through the
conduit hole at the bottom of
the unit
8 Release the ferrite core.
Step Procedure Points
1
2
3
Indoor heat exchanger thermistor
(R22045)
(R22132)
Clamp
Clip
(R11268)
1
2
3
Terminal strip
Wire
fixture
Connecting wire
(R24478)
1
2
3
(R18716)
[S1] Hook
Lock nut
Back
Conduit
Conduit mounting
plate
(R24421)
(R9501)
Ferrite core