Cooling Capacity | 7.1 kW |
---|---|
Heating Capacity | 8.0 kW |
Indoor Unit Dimensions (W x H x D) | 990 x 298 x 263 mm |
Outdoor Unit Dimensions (W x H x D) | 840 x 595 x 300 mm |
Power Supply | 220-240 V, 50 Hz |
Steps to remove the front panel by releasing shafts and hooks.
Steps to remove thermistor, wire fixture, terminal strip, and ferrite core.
Steps to disconnect harness, remove screw, and lift out electrical box.
Steps to release harness, unfasten hooks, and remove the signal receiver unit.
Steps to remove display PCB and control PCB by unfastening hooks and disconnecting connectors.
Release interlock rod, remove screw, and detach swing motor unit.
Remove lower fixing plate, fan motor, and vibration absorber.
Lift up and remove the indoor heat exchanger unit.
Loosen fan rotor screw, remove fan motor and fan rotor.