EasyManua.ls Logo

Daikin FTL50UV16V7 - User Manual

Daikin FTL50UV16V7
33 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
IKIN
3
P
719813-10 M
DAIKIN ROOM AIR CONDITIONER
OPERION MANUAL
(�
l
D
>

�7

I



 
 
 


 


3
P
719813-10 M
Question and Answer IconNeed help?

Do you have a question about the Daikin FTL50UV16V7 and is the answer not in the manual?

Summary

General Safety Precautions

Understanding Safety Classifications

Explanation of WARNING and CAUTION labels for safe operation.

Hazard Prevention Guidelines

Covers fire, explosion, injury, and property damage risks.

Safe Operational Practices

Covers proper use, placement, and handling to avoid hazards.

Pre-Operation Setup and Tips

Basic Operation Modes

DRY, COOL, and FAN Modes

Explains how to start, stop, and adjust settings for basic modes.

Airflow Direction and Child Lock

Timer and Sleep Functions

Filter Maintenance and Cleaning

Troubleshooting Critical Issues and Disposal

Immediate Service Requirements

Lists critical symptoms requiring immediate service center contact.

Troubleshooting Error Codes

Remote Controller Fault Diagnosis

Explains how to access and interpret error codes displayed by the remote controller.

Installation Safety Precautions

Understanding Safety Symbols and Classifications

Explains the meaning of WARNING, CAUTION, and safety marks.

Installation Hazard Warnings

Covers critical risks like electric shock, fire, and refrigerant leaks during installation.

Installation Site Selection

Indoor Unit Installation Steps

Mounting Plate Installation Procedure

Step-by-step guide for securely installing the mounting plate.

Unit Mounting and Piping

Covers attaching the unit to the mounting plate and routing pipes.

Indoor Unit Connections

Wiring Installation

Instructions for connecting inter-unit and power supply wires.

Installation Diagrams and Specifications

Outdoor Unit Piping and Connections

Pipe Flaring Procedure

Detailed steps for preparing refrigerant pipe ends for connection.

Refrigerant Pipe Connections and Torque

Instructions for connecting pipes and tightening flare nuts with specified torque.

Outdoor Unit Operations

Purging Air and Checking for Gas Leaks

Critical steps for removing air and checking for refrigerant leaks.

Wiring and Drain Connections

Instructions for electrical wiring and drain work for the outdoor unit.

Trial Operation and System Checks

Conducting Trial Operation

Steps for performing initial operation tests and checks.

Summary

General Safety Precautions

Understanding Safety Classifications

Explanation of WARNING and CAUTION labels for safe operation.

Hazard Prevention Guidelines

Covers fire, explosion, injury, and property damage risks.

Safe Operational Practices

Covers proper use, placement, and handling to avoid hazards.

Pre-Operation Setup and Tips

Basic Operation Modes

DRY, COOL, and FAN Modes

Explains how to start, stop, and adjust settings for basic modes.

Airflow Direction and Child Lock

Timer and Sleep Functions

Filter Maintenance and Cleaning

Troubleshooting Critical Issues and Disposal

Immediate Service Requirements

Lists critical symptoms requiring immediate service center contact.

Troubleshooting Error Codes

Remote Controller Fault Diagnosis

Explains how to access and interpret error codes displayed by the remote controller.

Installation Safety Precautions

Understanding Safety Symbols and Classifications

Explains the meaning of WARNING, CAUTION, and safety marks.

Installation Hazard Warnings

Covers critical risks like electric shock, fire, and refrigerant leaks during installation.

Installation Site Selection

Indoor Unit Installation Steps

Mounting Plate Installation Procedure

Step-by-step guide for securely installing the mounting plate.

Unit Mounting and Piping

Covers attaching the unit to the mounting plate and routing pipes.

Indoor Unit Connections

Wiring Installation

Instructions for connecting inter-unit and power supply wires.

Installation Diagrams and Specifications

Outdoor Unit Piping and Connections

Pipe Flaring Procedure

Detailed steps for preparing refrigerant pipe ends for connection.

Refrigerant Pipe Connections and Torque

Instructions for connecting pipes and tightening flare nuts with specified torque.

Outdoor Unit Operations

Purging Air and Checking for Gas Leaks

Critical steps for removing air and checking for refrigerant leaks.

Wiring and Drain Connections

Instructions for electrical wiring and drain work for the outdoor unit.

Trial Operation and System Checks

Conducting Trial Operation

Steps for performing initial operation tests and checks.

Daikin FTL50UV16V7 Specifications

General IconGeneral
Star Rating3 Star
RefrigerantR32
Weight (Indoor Unit)11 kg
Weight (Outdoor Unit)35 kg
TypeSplit
Heating Capacity5.6 kW
Power Supply230V / 50Hz / 1 Phase