EasyManua.ls Logo

Daikin FTN25PV1L - User Manual

Daikin FTN25PV1L
60 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Wall Mounted
L/M/P/311 Series
TM-FT-0415-B
TECHNICAL MANUAL

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Daikin FTN25PV1L and is the answer not in the manual?

Summary

Features

Specifications

Application Information

Installations

Safety Precautions

Lists critical safety guidelines for installation personnel and the environment.

Installation Diagram

Illustrates the recommended placement and clearances for indoor and outdoor units.

Installation Of The Outdoor Unit

Details the proper positioning of the outdoor unit to prevent short circuits and ensure airflow.

Installation Clearances

Specifies minimum distances required around the outdoor unit for proper installation.

Installation Of The Indoor Unit

Guides on installing the indoor unit, considering sunlight, piping, and drainage.

Mounting Installation Plate

Explains how to securely mount the indoor unit's installation plate to the wall.

Water Drainage Piping

Reiterates the importance of correct drain pipe slope and provides visual examples.

Refrigerant Piping

Piping Length & Elevation

Explains how pipe length and bends affect performance and compressor reliability.

Piping Works And Flaring Technique

Details the correct methods for cutting, flaring, and preparing copper tubing.

Piping Connection To The Units

Guides on connecting refrigerant pipes to the indoor and outdoor units using flare nuts.

Vacuuming And Charging

Vacuuming The Piping And The Indoor Unit

Explains the necessity of vacuuming to remove moisture and air from the system.

Charge Operation

Details the process of adding the correct amount of refrigerant using a weighing machine.

Indicator Lights

LED Indicator Lights: Normal Operation And Fault Conditions For Cooling Unit

Tabulates the meaning of various LED light combinations for normal and fault states.

Special Precautions When Dealing With Refrigerant R410 A Unit

Check List Before Installation; Servicing

Provides a checklist of items and tools required specifically for R410A systems.

Handling and Installation Guildelines

Outlines precautions for handling R410A, emphasizing moisture avoidance and system vacuuming.

Wiring Diagrams

Indoor Unit

Presents the wiring diagram for the indoor unit of various models.

Outdoor Unit

Shows the wiring diagram for the outdoor unit of corresponding models.

Servicing and Maintenance

Air Filter (Indoor Unit)

Details the procedure and frequency for cleaning or replacing the indoor air filter.

Troubleshooting

Summary

Features

Specifications

Application Information

Installations

Safety Precautions

Lists critical safety guidelines for installation personnel and the environment.

Installation Diagram

Illustrates the recommended placement and clearances for indoor and outdoor units.

Installation Of The Outdoor Unit

Details the proper positioning of the outdoor unit to prevent short circuits and ensure airflow.

Installation Clearances

Specifies minimum distances required around the outdoor unit for proper installation.

Installation Of The Indoor Unit

Guides on installing the indoor unit, considering sunlight, piping, and drainage.

Mounting Installation Plate

Explains how to securely mount the indoor unit's installation plate to the wall.

Water Drainage Piping

Reiterates the importance of correct drain pipe slope and provides visual examples.

Refrigerant Piping

Piping Length & Elevation

Explains how pipe length and bends affect performance and compressor reliability.

Piping Works And Flaring Technique

Details the correct methods for cutting, flaring, and preparing copper tubing.

Piping Connection To The Units

Guides on connecting refrigerant pipes to the indoor and outdoor units using flare nuts.

Vacuuming And Charging

Vacuuming The Piping And The Indoor Unit

Explains the necessity of vacuuming to remove moisture and air from the system.

Charge Operation

Details the process of adding the correct amount of refrigerant using a weighing machine.

Indicator Lights

LED Indicator Lights: Normal Operation And Fault Conditions For Cooling Unit

Tabulates the meaning of various LED light combinations for normal and fault states.

Special Precautions When Dealing With Refrigerant R410 A Unit

Check List Before Installation; Servicing

Provides a checklist of items and tools required specifically for R410A systems.

Handling and Installation Guildelines

Outlines precautions for handling R410A, emphasizing moisture avoidance and system vacuuming.

Wiring Diagrams

Indoor Unit

Presents the wiring diagram for the indoor unit of various models.

Outdoor Unit

Shows the wiring diagram for the outdoor unit of corresponding models.

Servicing and Maintenance

Air Filter (Indoor Unit)

Details the procedure and frequency for cleaning or replacing the indoor air filter.

Troubleshooting

Daikin FTN25PV1L Specifications

General IconGeneral
BrandDaikin
ModelFTN25PV1L
CategoryAir Conditioner
LanguageEnglish

Related product manuals