8
Specication Data
FTV-PS
MODEL
INDOOR UNIT
FTV85PS
OUTDOOR UNIT
RC85A
Rated Capacity
kW 8.79
Btu/h 30,000
Rated Running Current A
13.10
Rated Power Consumption W
2,900
EER W/W
3.03
CSPF Wh/Wh
3.22
Power Factor (Rated) 0.96
Piping
Connections
Liquid mm 9.52
Gas mm 15.90
Refrigerant
Type R32
Charge kg
1.60
Max. Interunit Piping Length m 50
Max. Interunit Height Difference m 30
INDOOR UNIT
FTV85PS
Front Panel Colour WHITE
Airow Rate
Turbo CFM
950
High CFM
931
Medium CFM
760
Low CFM
661
Quiet CFM
569
Sound Pressure Level (H/M/L/Q) dBA
51/46/42/39
Fan
Type CROSS FLOW FAN
Drive DIRECT
Fan Motor
Type 1-PHASE SCR
Motor Output W
70
Running Current (Rated) A
0.51
Power Consumption (Rated) W
107
Air Direction Control UP, DOWN, LEFT, RIGHT
Air Filter SARANET
Dimensions (H x W x D) mm
310 X 1,289 X 240
Packaged Dimensions (H x W x D) mm
396 X 1,382 X 316
Weight kg 16.0
Condensate Drain Size mm 19.0
OUTDOOR UNIT
RC85A
Casing Colour IVORY WHITE
Airow Rate CFM
1,930
Sound Pressure Level dBA
54
Fan
Type PROPELLER
Drive DIRECT
Fan Motor
Type AC
Index of protection (IP) 23
Insulation Grade F
Running Current (Rated) A
0.58
Power Consumption (Rated) W
133
Motor Output W
66
Poles 6
Compressor
Type TWIN ROTARY
Oil type
RM-LP56EG OR EQUIVALENT
Oil amount cm
3
840
Running Current (Rated) A
12.0
Power Consumption (Rated) W
2660
Heat Exchanger Type FIN TUBE
Dimensions (H x W x D) mm
695 X 930 X 350
Packaged Dimensions (H x W x D) mm
760 X 1,084 X 473
Weight kg 53
ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 (NON-DUCTED UNIT) OR ISO 13253 (DUCTED UNIT).
Cooling
INDOOR: 27°CDB / 19°CWB
OUTDOOR: 35°CDB