EasyManua.ls Logo

Daikin FTXB09A User Manual

Daikin FTXB09A
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
INSTALLATION
MANUAL
R410A SPLIT SERIES
IM-5WMYJ(R)-0617(0)-DAIKIN USA
Part Number.: R08019046594
MODELS
FTXB09A RXB09A
FTXB12A RXB12A
FTXB18A RXB18A
FTXB24A RXB24A
FTKB09A RKB09A
FTKB12A RKB12A
FTKB18A RKB18A
FTKB24A RKB24A
Installation Manual
R410A Split Series
Manuel d’installation
Série split R410A
Manual de instalación
Serie Split R410A
English
Français
Español
CVR IM-5WMYJ(R)-0617(0)-DAIKIN U1 1CVR IM-5WMYJ(R)-0617(0)-DAIKIN U1 1 10/12/17 10:30:39 AM10/12/17 10:30:39 AM

Questions and Answers:

Daikin FTXB09A Specifications

General IconGeneral
BrandDaikin
ModelFTXB09A
CategoryAir Conditioner
LanguageEnglish

Summary

Safety Precautions

General Safety Warnings

Critical warnings for qualified personnel and installation risks, including shock and fire hazards.

Installation Cautions

Important cautions during installation, covering unit stability, wiring, and component handling.

Installation Diagrams and Clearances

Indoor Unit Installation Diagram

Visual guide for indoor unit installation placement and required clearances.

Outdoor Unit Installation (18/24) and Drain Work

Indoor Unit Installation

Mounting and Piping Installation Details

Refrigerant Piping Specifications

Allowable Piping Length

Details maximum allowable piping lengths and elevation differences for refrigerant lines.

Equivalent Length for Fittings

Table showing equivalent piping lengths for various fittings used in refrigerant lines.

Refrigerant Piping Techniques

Piping Works and Flaring

Techniques for pipe cutting, burr removal, flaring, and pipe protection.

Refrigerant Pipe Connection

Instructions for connecting refrigerant pipes, including torque specifications.

Electrical Wiring Connection

Wiring Diagram and Recommendations

Electrical wiring diagram, recommended wire type, and connection precautions.

R410A Handling and System Operations

R410A Refrigerant Precautions

Special precautions for handling R410A refrigerant due to its properties.

Vacuuming and Charging Procedures

Step-by-step guide for vacuuming the system and charging refrigerant.

Unit Storage and Troubleshooting

Troubleshooting Common Faults

Lists common faults, their causes, and recommended actions.