4 | Components
Service manual
50
RXJ20~50A + FTXJ-A(W)(S)(B)
Split Emura 3 R32
ESIE22-04 – 2022.04
ab
a Insulation
b Main PCB
2 Disconnect all connectors from the main PCB.
3 Disconnect the electrical power supply wiring from the wire terminals.
f
a
d
c
b
e
a Electrical power supply wiring
b Wire terminals
c Screws
d Wire clamp
e Screws
f Right side plate assembly
4 Remove the screws that fix the wire clamp.
draft–22/04/2022 08:50