Capacity Tables EDUS041111_a
28 Room Air Conditioners K-Series
FTXN15KVJU + RXN15KEVJU (60 Hz, 230 V)
Cooling
Heating
AFR 14.7
BF 0.18
Temp: Celsius
TC, SHC, PI: kW
INDOOR OUTDOOR TEMPERATURE (°CDB)
EWB EDB 20.0 25.0 30.0 32.0 35.0 40.0
°C °C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
14.020.04.473.420.964.263.321.054.063.221.143.983.181.183.853.121.243.653.021.25
16.022.04.673.360.964.473.261.064.263.171.154.183.131.194.063.081.243.852.991.25
18.025.04.873.530.974.673.451.064.463.361.154.383.321.194.263.271.254.053.191.26
19.426.75.013.550.974.813.471.074.603.391.164.523.351.19
4.40 3.31 1.25 4.20 3.23 1.26
22.030.05.283.610.985.073.541.074.873.471.164.793.441.204.663.391.264.463.321.27
24.032.05.483.520.995.283.461.085.073.391.174.993.361.214.873.321.264.663.261.27
Temp: Fahrenheit
TC, SHC: kBtu/h
PI: kW
INDOOR OUTDOOR TEMPERATURE (°FDB)
EWB EDB 68.0 77.0 86.0 89.6 95.0 104.0
°F °F TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
57.2 68.0 15.24 11.65 0.96 14.54 11.31 1.05 13.84 10.97 1.14 13.56 10.84 1.18 13.15 10.64 1.24 12.45 10.31 1.25
60.8 71.6 15.93 11.46 0.96 15.24 11.14 1.06 14.54 10.82 1.15 14.26 10.69 1.19 13.84 10.50 1.24 13.14 10.20 1.25
64.4 77.0 16.63 12.06 0.97 15.93 11.76 1.06 15.23 11.46 1.15 14.95 11.34 1.19 14.53 11.17 1.25 13.83 10.88 1.26
67.0 80.0 17.11 12.12 0.97 16.41 11.84 1.07 15.71 11.56 1.16 15.43 11.45 1.19
15.00 11.28 1.25 14.31 11.01 1.26
71.6 86.0 18.01 12.33 0.98 17.31 12.07 1.07 16.61 11.82 1.16 16.33 11.72 1.20 15.91 11.58 1.26 15.21 11.33 1.27
75.2 89.6 18.70 12.02 0.99 18.00 11.79 1.08 17.30 11.56 1.17 17.02 11.47 1.21 16.60 11.34 1.26 15.90 11.11 1.27
AFR 16.1
Temp: Celsius
TC, PI: kW
INDOOR OUTDOOR TEMPERATURE (°CWB)
EDB –15.0 –10.0 –5.0 0 6.0 10.0
°C TC PI TC PI TC PI TC PI TC PI TC PI
15.0 2.55 1.11 3.06 1.16 3.56 1.22 4.79 1.60 5.50 1.68 5.98 1.74
21.1 2.36 1.14 2.87 1.20 3.37 1.26 4.56 1.64
5.28 1.73 5.76 1.79
22.0 2.33 1.15 2.84 1.21 3.35 1.26 4.53 1.65 5.25 1.74 5.72 1.79
24.0 2.27 1.16 2.78 1.22 3.28 1.28 4.46 1.67 5.17 1.75 5.65 1.81
25.0 2.24 1.17 2.75 1.23 3.25 1.28 4.42 1.67 5.14 1.76 5.61 1.82
27.0 2.18 1.18 2.68 1.24 3.19 1.30 4.35 1.69 5.06 1.78 5.54 1.83
Temp: Fahrenheit
TC: kBtu/h
PI: kW
INDOOR OUTDOOR TEMPERATURE (°FWB)
EDB 5.0 14.0 23.0 32.0 43.0 50.0
°F TC PI TC PI TC PI TC PI TC PI TC PI
59.0 8.70 1.11 10.42 1.16 12.15 1.22 16.33 1.60 18.77 1.68 20.40 1.74
70.0 8.05 1.14 9.78 1.20 11.51 1.26 15.57 1.64
18.00 1.73 19.64 1.79
71.6 7.96 1.15 9.68 1.21 11.41 1.26 15.46 1.65 17.90 1.74 19.53 1.79
75.2 7.74 1.16 9.47 1.22 11.20 1.28 15.21 1.67 17.65 1.75 19.28 1.81
77.0 7.64 1.17 9.37 1.23 11.10 1.28 15.09 1.67 17.53 1.76 19.16 1.82
80.6 7.43 1.18 9.16 1.24 10.89 1.30 14.84 1.69 17.28 1.78 18.91 1.83