Operation manual
R32 split series
English
Operation manual
R32 split series
FTXP20L2V1B
FTXP25L2V1B
FTXP35L2V1B
FTXP50L2V1B
FTXP60L2V1B
FTXP71L2V1B

Table of Contents

Other manuals for Daikin FTXP20L2V1B

Questions and Answers

  • C
    Casey WalshAug 16, 2025
    What to do if my Daikin Air Conditioner suddenly stops operating?
    • W
      Walter BakerAug 16, 2025
      If your Daikin Air Conditioner system suddenly stops operating, check the following: * Ensure that the air inlet or outlet of both the outdoor and indoor units are not blocked. Remove any obstacles to allow free airflow. * Keep in mind that the air conditioner may stop operating after sudden large voltage fluctuations to protect the system. It should resume operation automatically after about 3 minutes.
  • D
    David PhillipsAug 19, 2025
    Why is the cooling or heating insufficient on my Daikin FTXP20L2V1B?
    • J
      Joseph BurgessSep 12, 2025
      If your Daikin Air Conditioner operates, but the cooling or heating is insufficient, consider the following: * Verify the airflow rate setting. * Check the temperature setting. * Confirm the airflow direction setting is appropriate. * Ensure that the air inlet or outlet of the outdoor or indoor unit is not blocked by any obstacles. Remove any obstructions to ensure free airflow.
  • M
    Mr. Mark FloresAug 22, 2025
    What to do if my Daikin FTXP20L2V1B Air Conditioner has an abnormal function during operation?
    • S
      Susan RoachAug 22, 2025
      If your Daikin Air Conditioner experiences an abnormal function during operation, possibly due to lightning or radio waves, try turning the breaker OFF and then back ON.
  • Q
    qduffyAug 25, 2025
    Why does my Daikin FTXP20L2V1B not operate at all?
    • M
      Michelle ClarkAug 26, 2025
      If your Daikin Air Conditioner system does not operate at all, here are a few things to check: * Ensure there is no power failure and wait until power is restored. The system should restart automatically after power is restored. * Check if a fuse has blown or a breaker is activated. Replace the fuse or reset the breaker if needed. * Check the batteries in the user interface.
  • C
    casey55Aug 28, 2025
    What to do if Daikin FTXP20L2V1B operates but cooling or heating is insufficient (air is NOT blown from the unit)?
    • S
      Shawn HollandAug 28, 2025
      If your Daikin Air Conditioner operates, but cooling or heating is insufficient and no air is blown from the unit, it might be in one of these states: * The air conditioner may be warming up for heating operation. Please wait 1 to 4 minutes. * The unit may be in defrost operation.
  • E
    Elizabeth KeyAug 31, 2025
    What to do if Daikin Air Conditioner operates but cooling or heating is insufficient (air is blown from the unit)?
    • R
      rgrantAug 31, 2025
      If your Daikin Air Conditioner operates, but cooling or heating is insufficient and air is blown from the unit, consider the following: * Check if the air filters are clogged and clean them if necessary. * Ensure all doors and windows are closed to prevent wind from entering. * Verify if the unit is operating in Econo mode. * Check for any furniture directly under or next to the indoor unit and move it.
  • S
    stanley74Sep 3, 2025
    What to do if other electric appliances start to operate when I use Daikin Air Conditioner?
    • B
      Benjamin AndrewsSep 3, 2025
      If other electric appliances start to operate when using your Daikin Air Conditioner, move the other appliances away, and contact your dealer.
  • B
    Benjamin HansenSep 6, 2025
    How to fix a blank user interface display on my Daikin FTXP20L2V1B Air Conditioner?
    • B
      Brian SavageSep 6, 2025
      If the user interface display of your Daikin Air Conditioner is blank, replace the batteries of the user interface.
  • L
    Lindsey MorrisSep 9, 2025
    What to do if Daikin FTXP20L2V1B Air Conditioner unit does not receive signals from the user interface?
    • B
      Brian CalhounSep 9, 2025
      If the Daikin Air Conditioner unit does not receive signals from the user interface, check the following: * Check the batteries of the user interface. * Make sure that the transmitter is not exposed to direct sunlight. * Check if there are any electronic starter type fluorescent lamps in the room. Contact your dealer.
  • S
    scottjonSep 12, 2025
    What to do if malfunction code appears on Daikin Air Conditioner?
    • J
      Joseph ParkSep 12, 2025
      If the user interface display indicates the unit number, the operation lamp flashes, and a malfunction code appears on your Daikin Air Conditioner, notify your installer and report the malfunction code.

Daikin FTXP20L2V1B Specifications

General IconGeneral
Cooling Capacity2.0 kW
Heating Capacity2.5 kW
Energy Efficiency RatingA++
Indoor Unit Dimensions (HxWxD)286 x 770 x 225 mm
Outdoor Unit Dimensions (HxWxD)550 x 658 x 275 mm
Weight (Indoor Unit)9 kg
RefrigerantR-32
SEER6.1
TypeSplit System
Noise Level (Indoor Unit)19 dB
Noise Level (Outdoor Unit)46 dBA
Sound Pressure Level (Cooling)19 dB