8 Disposal
Installation manual
12
(A)(F)TXP20~35L5V1B + FTXF20~35A5V1B + FTXF20~25B5V1B
Daikin room air conditioner
3P519299-1H – 2019.09
Prerequisite: Test run should be performed in accordance with the
operation manual of the indoor unit to make sure that all functions
and parts are working properly.
1 In cooling mode, select the lowest programmable temperature.
In heating mode, select the highest programmable temperature.
Test run can be disabled if necessary.
2 When the test run is finished, set the temperature to a normal
level. In cooling mode: 26~28°C, in heating mode: 20~24°C.
3 The system stops operating 3 minutes after the unit is turned
OFF.
7.2.1 To perform a test run in winter season
When operating the air conditioner in Cooling mode in winter, set it
to test run operation using the following method.
For FTXP and ATXP units
1 Press , , and simultaneously.
2 Press .
3 Select .
4 Press .
5 Press to switch the system on.
Result: Test run operation will stop automatically after about
30minutes.
6 To stop operation, press .
For FTXF units
7 Press to switch the system on.
8 Press the centre of , , and simultaneously.
9 Press twice.
Result: will appear on the display. Test run operation is
selected. Test run operation will stop automatically after about
30minutes.
10 To stop operation, press .
INFORMATION
Some of the functions CANNOT be used in the test run
operation mode.
If a power failure occurs during operation, the system automatically
restarts immediately after power is restored.
8 Disposal
Dismantling of the unit and treatment of the refrigerant, oil and other
parts MUST comply with the applicable legislation.