What to do if Daikin FTXP35M5V1B9 Air Conditioner leaks water?
- EEddie WilkersonAug 19, 2025
If water leaks from the unit, immediately stop the operation.
What to do if Daikin FTXP35M5V1B9 Air Conditioner leaks water?
If water leaks from the unit, immediately stop the operation.
What to do if my Daikin FTXP35M5V1B9 Air Conditioner system suddenly stops?
If your Daikin Air Conditioner system stops operating suddenly, first check if any obstacles block the air inlet or outlet of the outdoor or indoor unit. Remove any obstructions to ensure free airflow. Also, the air conditioner might stop temporarily due to voltage fluctuations to protect the system. In this case, it will automatically resume operation after about 3 minutes.
Why is my Daikin Air Conditioner not cooling or heating sufficiently even when air is blowing?
If your Daikin Air Conditioner is running, but the cooling or heating isn't sufficient, check the following: * Ensure that the air filters are clean. If they are clogged, clean them. * Close any open doors or windows to prevent wind from entering. * Make sure the unit is not in Econo operation mode. * Check for any furniture placed directly under or next to the indoor unit and move it.
Why my Daikin FTXP35M5V1B9 does not operate at all?
If your Daikin Air Conditioner system does not operate at all, check for these possible causes: * Verify that there is no power failure and wait for the power to be restored. Note that the system restarts automatically after a power failure. * Check if a fuse has blown or a breaker has been activated. Replace the fuse or reset the breaker if necessary. * Check the batteries in the user interface and replace them if needed.
Why is my Daikin FTXP35M5V1B9 Air Conditioner cooling or heating insufficient?
If your Daikin Air Conditioner is running, but cooling or heating is insufficient, take the following steps: * Check the airflow rate setting. * Check the temperature setting. * Ensure the airflow direction setting is appropriate. * Make sure that the air inlet or outlet of the outdoor or indoor unit is not blocked by obstacles. Remove any obstructions to allow free airflow.
What to do if my Daikin FTXP35M5V1B9 Air Conditioner blows no air but cooling or heating is insufficient?
If your Daikin Air Conditioner is operating, but cooling or heating is insufficient, and no air is blowing from the unit, it might be in one of these states: * The air conditioner may be warming up for heating operation. Wait for 1 to 4 minutes. * The unit may be in defrost operation.
Why is my Daikin FTXP35M5V1B9 unit not responding to the user interface?
If your Daikin Air Conditioner unit does not receive signals from the user interface, consider the following: * Check and replace the batteries of the user interface. * Ensure that the transmitter is not exposed to direct sunlight. * Check if there are any electronic starter type fluorescent lamps in the room.
What to do if Daikin Air Conditioner user interface displays unit number, operation lamp flashes and malfunction code appears?
If the user interface display indicates the unit number, the operation lamp flashes and a malfunction code appears, notify your installer and report the malfunction code.
What to do if the operation switch does NOT work well on Daikin Air Conditioner?
If the operation switch does not work well, turn OFF the power supply.
How to fix a blank user interface display on my Daikin FTXP35M5V1B9?
If the user interface display of your Daikin Air Conditioner is blank, replace the batteries in the user interface.
Model | FTXP35M5V1B9 |
---|---|
Cooling Capacity | 3.5 kW |
Heating Capacity | 4.0 kW |
Energy Efficiency Ratio (EER) | 3.21 |
Seasonal Energy Efficiency Ratio (SEER) | 6.1 |
Energy Efficiency Class (Cooling) | A++ |
Energy Efficiency Class (Heating) | A+ |
Refrigerant | R-32 |
Indoor Unit Dimensions (WxHxD) | 770 x 286 x 225 mm |
Indoor Unit Weight | 9 kg |
Outdoor Unit Dimensions (WxHxD) | 658 x 550 x 275 mm |
Type | Split |
Power Supply | 220-240V / 50Hz |
Critical warnings and precautions for safe operation and maintenance by users.
Explains how to select operation modes and set the desired temperature for heating, cooling, or fan operations.
Provides instructions on how to adjust the fan speed or airflow volume.
Details how to adjust the direction of airflow using vertical and horizontal swing options.
Explains how to clean and maintain the standard air filters for optimal performance.
Explains how to view and interpret error codes displayed on the user interface for fault diagnosis.