Si041259EA Electrical Box
Removal Procedure 7
5
Disconnect the
connectors [S1] [S41].
[S1]: fan motor
[S41]: swing motors
6
Release the harnesses
for the fan motor and
swing motors from the
hooks.
7
Remove the screw and
detach the earth /
ground wire.
Be careful not to lose the clip
of the thermistor.
8
Pull out the indoor heat
exchanger thermistor.
9
Remove the screw of
the electrical box.
Unfasten the hook at the
back.
10
Lift up the electrical box
and pull it out.
Step
Procedure Points
Hook
[S1]
[S41]
Hook
(
R19035
)
Indoor heat exchanger thermistor
(R19036)
Earth / ground wire
Clip
(R11268)
(R19037)
Electrical box