15
NOTE
Energy saving operation
•Ifnopresencedetectedintheroomfor20minutes,theenergysavingoperationwillstart,andtheINTELLIGENTEYElampgoesoff.
Ifhumanmovementisdetectedagain,theINTELLIGENTEYElamplightsupandenergysavingoperationterminates.
•Thisoperationchangesthetemperatureby−2°CinHEAT/+2°CinCOOL/+2°CinDRYoperationfromthesettemperature.
Whentheroomtemperatureexceeds30°C,theoperationchangesthetemperatureby+1°CinCOOL/+1°CinDRYoperationfromtheset
temperature.
•ThisoperationdecreasestheairowrateslightlyinFANoperationonly.
Notes on INTELLIGENT EYE operation
•Applicationrangeisasfollows.
90°
55°
7m
55°
Vertical angle 90°
(Side view)
Horizontal
angle 110°
(Top view)
7m
•Theairconditionermayswitchtotheenergy-savingoperationeveniftherearepeopleintheareas.
Thismayoccurdependingontheclothesthepeoplearewearing,ifthereisnomovementofthepeopleintheareas.
•Duetothepositionofthesensor,peoplemightbeexposedtotheairowoftheindoorunitiftheyareclosetothefrontsideoftheindoorunit.
•Thesensorcouldalsomistakenlydetectpets,sunlight,utteringcurtainsandlightreectedoffofmirrorsaspassers-by.
•Thesensormaynotdetectmovingobjectsfurtherthan7maway.(Pleaseseetheapplicationrange)
•Sensordetectionsensitivitychangesaccordingtotheindoorunitlocation,thespeedofpassers-by,temperaturerange,etc.
•NIGHTSETmode
Page 21
willnotswitchonduringuseofINTELLIGENTEYEoperation.
INTELLIGENT EYE Operation
Useful Functions Useful Functions
01_EN_3P492259-18L.indd 15 12/13/2019 2:08:20 PM