SPLIT SYSTEM Air Conditioner
OPERATION MANUAL
MODELS
(Floor standing type)
FVQ71CVEB
FVQ100CVEB
FVQ125CVEB
FVQ140CVEB
English
Deutsch
Français
Español
Italiano
Nederlands
Portugues
3P170549-14G.book Page 1 Friday, October 28, 2011 3:04 AM

Other manuals for Daikin FVQ71CVEB

Questions and Answers

  • J
    jeremiahsmithAug 19, 2025
    What to do if my Daikin Air Conditioner does not operate at all?
    • K
      Kevin GuerreroSep 12, 2025
      If your Daikin Air Conditioner isn't operating, check the following: * Ensure no fuse has blown. Turn off the power supply. * See if the power circuit breaker is blown. Turn the power on with the power circuit breaker switch in the off position. * Check for a power failure. Wait until power is restored.
  • S
    Steven RobertsAug 22, 2025
    What to do if water leaks from Daikin FVQ71CVEB Air Conditioner unit?
    • B
      brianbenitezAug 22, 2025
      If water is leaking from your Daikin Air Conditioner unit, stop the operation immediately.
  • J
    john59Aug 26, 2025
    What to do if the ON/OFF switch does not properly work on my Daikin FVQ71CVEB Air Conditioner?
    • A
      Ashley HigginsAug 26, 2025
      If the ON/OFF switch on your Daikin Air Conditioner does not work properly, turn off the main power switch.
  • J
    Jacqueline ConnerAug 28, 2025
    What to do if Daikin Air Conditioner detects multiple master units?
    • A
      alyssawarnerAug 28, 2025
      If your Daikin Air Conditioner detects multiple master units, connect the remote controller to only one indoor unit.
  • D
    Dawn MillerAug 31, 2025
    What to do if Daikin FVQ71CVEB Air Conditioner has gas shortage due to clogging in refrigerant piping?
    • A
      Allison RoweAug 31, 2025
      If you suspect clogging in the refrigerant piping system of your Daikin Air Conditioner, check for a failure to open the stop valve and any clogging within the refrigerant system.
  • C
    Christina BurnsSep 3, 2025
    What does excess indoor units connected error mean on Daikin FVQ71CVEB Air Conditioner?
    • S
      Stacey MorrisonSep 3, 2025
      This error will be displayed if five or more indoor units are connected to your Daikin Air Conditioner.
  • K
    Kathleen SchneiderSep 6, 2025
    Why Daikin FVQ71CVEB Air Conditioner unit started or stopped without pressing the on/off button?
    • T
      Thomas LopezSep 6, 2025
      If your Daikin Air Conditioner started or stopped without pressing the ON/OFF button: * Verify that the ON/OFF timer operation is not in use. Turn off the ON/OFF timer. * Check if a remote control device is connected. Contact the central control room that directed the stop. * See if the display for centralized control is lit. Contact the central control room that directed the stop.
  • E
    Erika FrancoSep 9, 2025
    What to do if a safety device frequently actuates on Daikin Air Conditioner?
    • T
      thomasjonathanSep 9, 2025
      If a safety device such as a fuse, a power circuit breaker, or an earth leakage breaker frequently actuates on your Daikin Air Conditioner, do not turn on the main power switch.
  • T
    tchristensenSep 12, 2025
    Why does my Daikin Heat Pump emit an odor?
    • O
      okellySep 12, 2025
      If your Daikin Heat Pump emits an odor, it's likely due to room smells and cigarette odors that have accumulated inside the indoor unit. To resolve this, the inside of the indoor unit must be cleaned.
  • D
    Diane HillNov 15, 2025
    Why Daikin Air Conditioner does not sufficiently cool or heat?
    • L
      Laura MooreNov 15, 2025
      There are several reasons why your Daikin Air Conditioner might not be cooling or heating sufficiently: * The air inlet or outlet of the indoor or outdoor unit may be blocked by obstacles. Remove any obstacles to ensure proper ventilation. * The air filter may be clogged. A qualified service person should clean the air filters. * The set temperature may not be appropriate. Adjust the temperature, airflow rate, and discharge direction accordingly. * The FAN SPEED button may be set to LOW SPEED. Adjust the settings for optimal performance. * The airflow angle may not be proper. Adjust the airflow angle. * Doors or windows may be open, allowing wind to enter. Close them to prevent this. * Direct sunlight may be entering the room (when cooling). Use curtains or blinds to block s...

Summary

Disposal Requirements

Product Disposal Guidelines

Guidelines for proper disposal of electrical and electronic products and batteries.

Refrigerant Information

Refrigerant Type and GWP Details

Details the type of refrigerant and its global warming potential.

Before Operation

System Control Options Overview

Information on standard, group, and two remote control systems for the unit.

Unit Parts Identification

Identifies and describes the function of various unit components.

Safety Precautions

Warning and Caution Definitions

Defines the severity levels for safety warnings and cautions.

General Safety Precautions

Crucial safety advice including handling malfunctions, installation, and environmental factors.

Specific Safety Precautions

Electric Shock Warning

Operation Range

Cooling Operation Conditions

Specifies the valid outdoor and indoor temperature/humidity ranges for cooling.

Heating Operation Conditions

Specifies the valid outdoor and indoor temperature/humidity ranges for heating.

Installation Site Requirements

Location Selection Guidelines

Guidance on suitable and unsuitable locations for installing the unit.

Wiring and Noise Considerations

Requirements for electrical wiring, noise minimization, and drain piping.

Operation Procedure

System Start-up Guide

Steps for starting the unit, including pre-operation checks and timing.

Operation Characteristics

Cooling and Heating Performance

Explains system behavior during cooling and heating operations.

Defrost and Humidity Control

Describes automatic defrost cycles and humidity control (Program Dry).

Airflow Direction Control

Instructions on adjusting airflow direction using the remote controller or manually.

Vertical Airflow Adjustment

Details manual adjustment of vertical airflow flaps for optimal air distribution.

Optimum Operation

Maximizing Performance and Efficiency

Tips to optimize system performance and efficiency during operation.

Temperature and Airflow Settings

Guidance on setting room temperature and airflow direction for comfort.

Maintenance

Filter Cleaning and Indicators

Information on filter cleaning indicators and the cleaning procedure.

Cleaning Unit Exterior and Parts

Instructions for cleaning the air outlet, grilles, exterior, and remote controller.

Seasonal Use Preparation

Start-up and Shutdown Procedures

Procedures for preparing the unit after inactivity and for long-term shutdown.

Non-Malfunction Symptoms

System Start-up Delays

Explains why the system may not start immediately after button presses or power restoration.

Operation Interruption and Fan Speed

Addresses temporary operation stops and fan speed discrepancies.

Airflow Direction and Mist Issues

Covers airflow direction mismatches and the cause of white mist formation.

Unit Noise Explanations

Describes common sounds produced by the unit during operation and their causes.

Dust, Odors, and Cooling Issues

Explains dust emission, unit odors, and ineffective cooling/heating.

Trouble Shooting

System Not Operating or Stopping

Troubleshooting steps for systems that do not operate or stop unexpectedly.

Insufficient Cooling or Heating

Diagnosing reasons for insufficient cooling or heating performance.

Fan Speed, Airflow, and Environment

Troubleshooting fan speed, airflow, and environmental influences.

Unintended Operation and Malfunctions

Investigates unintentional operation and actions for malfunction indicators.

Safety Device and Leakage Issues

Guidance for frequent tripping of safety devices and water leakage.

Daikin FVQ71CVEB Specifications

General IconGeneral
BrandDaikin
ModelFVQ71CVEB
CategoryAir Conditioner
LanguageEnglish