EasyManua.ls Logo

Daikin FVQ125CVEB - User Manual

Daikin FVQ125CVEB
18 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
SPLIT SYSTEM Air Conditioner
OPERATION MANUAL
MODELS
(Floor standing type)
FVQ71CVEB
FVQ100CVEB
FVQ125CVEB
FVQ140CVEB
English
Deutsch
Français
Español
Italiano
Nederlands
Portugues
3P170549-14G.book Page 1 Friday, October 28, 2011 3:04 AM

Other manuals for Daikin FVQ125CVEB

Questions and Answers

  • M
    Mary FernandezAug 19, 2025
    What to do if my Daikin FVQ125CVEB does not operate at all?
    • K
      kristin54Sep 12, 2025
      If your Daikin Air Conditioner isn't operating, check the following: * Ensure no fuse has blown. Turn off the power supply. * See if the power circuit breaker is blown. Turn the power on with the power circuit breaker switch in the off position. * Check for a power failure. Wait until power is restored.
  • E
    Eileen BoothAug 22, 2025
    What to do if water leaks from Daikin Air Conditioner unit?
    • A
      Andrew MitchellAug 22, 2025
      If water is leaking from your Daikin Air Conditioner unit, stop the operation immediately.
  • C
    Crystal HarrisAug 25, 2025
    What to do if the ON/OFF switch does not properly work on my Daikin FVQ125CVEB Air Conditioner?
    • K
      Kristin HillAug 26, 2025
      If the ON/OFF switch on your Daikin Air Conditioner does not work properly, turn off the main power switch.
  • A
    Alicia StanleyAug 28, 2025
    What to do if Daikin Air Conditioner detects multiple master units?
    • A
      Ashley HayesAug 28, 2025
      If your Daikin Air Conditioner detects multiple master units, connect the remote controller to only one indoor unit.
  • M
    michaelperezAug 31, 2025
    What to do if Daikin Air Conditioner has gas shortage due to clogging in refrigerant piping?
    • X
      xphillipsAug 31, 2025
      If you suspect clogging in the refrigerant piping system of your Daikin Air Conditioner, check for a failure to open the stop valve and any clogging within the refrigerant system.
  • T
    Taylor OwensSep 3, 2025
    What does excess indoor units connected error mean on Daikin Air Conditioner?
    • P
      Pamela SuarezSep 3, 2025
      This error will be displayed if five or more indoor units are connected to your Daikin Air Conditioner.
  • C
    Christine WardSep 6, 2025
    Why Daikin Air Conditioner unit started or stopped without pressing the on/off button?
    • A
      Amanda PattonSep 6, 2025
      If your Daikin Air Conditioner started or stopped without pressing the ON/OFF button: * Verify that the ON/OFF timer operation is not in use. Turn off the ON/OFF timer. * Check if a remote control device is connected. Contact the central control room that directed the stop. * See if the display for centralized control is lit. Contact the central control room that directed the stop.
  • O
    olivia04Sep 9, 2025
    What to do if a safety device frequently actuates on Daikin Air Conditioner?
    • M
      Melanie RichardsonSep 9, 2025
      If a safety device such as a fuse, a power circuit breaker, or an earth leakage breaker frequently actuates on your Daikin Air Conditioner, do not turn on the main power switch.
  • A
    Ashley JosephSep 12, 2025
    Why does my Daikin Heat Pump emit an odor?
    • L
      Luis StoneSep 12, 2025
      If your Daikin Heat Pump emits an odor, it's likely due to room smells and cigarette odors that have accumulated inside the indoor unit. To resolve this, the inside of the indoor unit must be cleaned.
  • B
    Billy GarrettNov 15, 2025
    Why Daikin FVQ125CVEB Air Conditioner does not sufficiently cool or heat?
    • D
      Deborah ThompsonNov 15, 2025
      There are several reasons why your Daikin Air Conditioner might not be cooling or heating sufficiently: * The air inlet or outlet of the indoor or outdoor unit may be blocked by obstacles. Remove any obstacles to ensure proper ventilation. * The air filter may be clogged. A qualified service person should clean the air filters. * The set temperature may not be appropriate. Adjust the temperature, airflow rate, and discharge direction accordingly. * The FAN SPEED button may be set to LOW SPEED. Adjust the settings for optimal performance. * The airflow angle may not be proper. Adjust the airflow angle. * Doors or windows may be open, allowing wind to enter. Close them to prevent this. * Direct sunlight may be entering the room (when cooling). Use curtains or blinds to block s...

Summary

What to Do Before Operation

System and Control System Types

Describes heat pump, cooling only, group control, and two remote controller systems.

Names and Functions of Parts

Lists and describes the components of the indoor and outdoor units.

Safety Precautions

Warning and Caution Classifications

Explains the meaning of WARNING and CAUTION labels for safety.

Handling Risks and Electrical Safety

Covers potential hazards like exposure to air, refrigerant leaks, improper installation, and electrical safety.

Operation Range

Installation Site Requirements

Installation Location Considerations

Details suitable and unsuitable places for unit installation, including environmental factors.

Wiring and Electrical Safety

Specifies requirements for wiring installation and electrical safety compliance.

Noise and Vibration Management

Guides on selecting locations to minimize running noise and vibrations.

Drain Piping Installation

Emphasizes proper drain piping for complete drainage and preventing water leakage.

Operation Procedure

Operation Characteristics

Cooling Operation Characteristics

Explains cooling operation behavior, including frost formation and DEFROST OPERATION.

Heating Operation Characteristics

Details heating operation, including start-up time and DEFROST OPERATION.

Airflow Direction Adjustment

Left and Right Airflow Control

Explains manual and automatic adjustment of left/right airflow flaps.

Up and Down Airflow Control

Details how to adjust airflow direction vertically by hand.

Adjusting Airflow: How-to Guide

Provides instructions on adjusting horizontal and vertical airflow flaps for optimal comfort.

Maintenance (For Service Personnel)

Air Filter Cleaning Procedure

Details when and how to clean the air filter, including reset procedure.

Not a Malfunction of the Air Conditioner

System Does Not Operate

Explains reasons for system non-operation and normal delays.

Operation Stops Occasionally

Addresses intermittent operation stops and potential causes like noise interference.

Fan Speed Discrepancies

Explains why fan speed might not match settings during certain operations.

Airflow Direction Issues

Covers situations where airflow direction differs from settings or remote control display.

White Mist or Noise Phenomena

Explains white mist and various operational noises.

Troubleshooting Common Issues

System Failure to Start

Steps to check when the system fails to start, including power and circuit breaker issues.

System Stops After Operation

Checks for blockages or clogged filters when the system stops after completion.

Performance Issues (Insufficient Cooling;Heating)

Addresses issues of insufficient cooling/heating, checking for blockages, filters, and settings.

Daikin FVQ125CVEB Specifications

General IconGeneral
CategoryAir Conditioner
Cooling Capacity12.5 kW
Heating Capacity14.0 kW
Power SourceElectric
Outdoor Unit Dimensions (HxWxD)990 x 940 x 320 mm
RefrigerantR410A
Indoor Unit Dimensions (HxWxD)235 x 1590 x 690 mm
Noise Level (Outdoor)49 dB
TypeCeiling Suspended Unit

Related product manuals