82
Troubleshooting
Troubleshooting
Model Board
FWMT02/03/04/05/06C 50WJWXX
FWMJC6/8/9/11/13B W3
FWMJCC2/4/5B W2
FWPMM3/4/6/7/8/9/11/12/14/16 W2
UAHMM20/25/30/40 N/A
Self Diagnostic Table - 50WJWXX Board
COOL/HEAT
(GREEN/RED)
Normal Operation/Fault Indication Action Error Code
Green
Cool mode - -
Red
Heat mode - -
Timer on - -
Sleep mode on - -
Fan mode on - -
Dry mode on - -
1 time
Room air sensor contact
Loose/Short
Call your dealer
Blink E1
2 times
Indoor coil sensor open/short
Call your dealer
Blink E2
3 times
Pipe water temperature poor - Blink E4
1 time
Pipe water temperature bad - Blink E5
6 times
Hardware error (tact switch pin short)
Call your dealer
Blink E8
4 times
No feedback from indoor fan
Call your dealer
Blink E9
ON
ON or OFF
Blinking