TECHNICAL MANUAL
Chilled Water Fan Coil Units
FWMT, FWMJC(C), FWKE, FWPMM, UAHMM Series
FWMT FWMJC/FWKE
FWMJCC
FWPMM
UAHMM
TM-FCU-W-SG-A3

Other manuals for Daikin FWPMM9AV1

Questions and Answers

  • E
    Elizabeth WhiteAug 10, 2025
    What to do if my Daikin FWPMM9AV1 does not operate?
    • D
      Dale VelasquezAug 10, 2025
      If your Daikin Fan isn't operating, there are a few potential causes. First, there may be a power failure, or the fuse might need replacement; check the power supply and replace the fuse if necessary. Second, the power plug could be disconnected; ensure it is properly connected. Finally, the delay timer may be set incorrectly; review and adjust the delay timer settings.
  • S
    smithcodyAug 17, 2025
    Why is the air flow too low in my Daikin FWPMM9AV1 Fan?
    • C
      christopher14Aug 17, 2025
      If the air flow in your Daikin Fan is too low, it could be due to a few reasons. The air filter might be dirty, so try cleaning or replacing it. Also, the air suction and discharge could be clogged, so clear any obstructions. Finally, the regulated temperature might not be high enough, so increase the regulated temperature setting.
  • D
    Dustin Gonzalez MDAug 25, 2025
    How to eliminate bad odor from Daikin FWPMM9AV1 Fan discharge air flow?
    • S
      Samuel WatkinsAug 26, 2025
      A bad odor from your Daikin Fan's discharge air flow may be caused by particles from cigarettes, smoke, perfume, etc., that have adhered to the coil. Clean the coil to remove these odors.
  • E
    Eric FoleySep 1, 2025
    What to do if there is condensation on the front air grille of my Daikin FWPMM9AV1 Fan?
    • B
      Billy WangSep 1, 2025
      Condensation on the front air grille of your Daikin Fan's indoor unit can occur due to air humidity after a long period of operation. Maintain operation and ensure proper humidity control. Also, the set temperature might be too low; increase the temperature setting and operate the unit at high fan speed.

Summary

Application Information

Installation Guide

System Configuration

Configures system jumpers for different modes (Heatpump, Cooling) and applications (Valve, Valveless).

Jumper Settings & Control Options

Details jumper settings and control options for specific model series.

Controller Board Model Selection

Explains model selection for controller boards based on system type and functions.

Fan Performance Chart

Engineering & Physical Data

Engineering Data - FWMT Series

Technical specifications for FWMT series fan coil units, including capacity, power, and dimensions.

Engineering Data - FWMJCC Series

Technical specifications for FWMJCC series fan coil units, including capacity, power, and dimensions.

Engineering Data - FWMJC Series

Technical specifications for FWMJC series fan coil units, including capacity, power, and dimensions.

Engineering Data - FWKE Series

Technical specifications for FWKE series fan coil units, including capacity, power, and dimensions.

Engineering Data - FWPMM Series

Technical specifications for FWPMM series fan coil units, including capacity, power, and dimensions.

Engineering Data - UAHMM Series

Technical specifications for UAHMM series fan coil units, including capacity, power, and dimensions.

Outlines & Dimensions

Wiring Diagrams

FWMT02-06 C Wiring Diagram

Illustrates the wiring schematic for FWMT02-06C indoor units.

FWJC6-13 B Wiring Diagram

Illustrates the wiring schematic for FWJC6-13B indoor units.

FWJCC2-5 B Wiring Diagram

Shows the wiring schematic for FWJCC2-5B indoor units.

FWKE05-08 E Wiring Diagram

Illustrates the wiring schematic for FWKE05-08E indoor units.

FWKE11 E Wiring Diagram

Shows the wiring schematic for FWKE11E indoor units.

Service & Maintenance

Troubleshooting

Self Diagnostic Table - 50 WJWXX Board

Lists fault indications, actions, and error codes for the 50WJWXX board.

Self Diagnostic Table - W2 Board

Details fault indications, actions, and error codes for the W2 board.

Self Diagnostic Table - W3 Board

Lists fault indications, actions, and error codes for the W3 board.

Self Diagnostic Table - W3 DC Board

Provides fault indications, actions, and error codes for the W3DC board.