5 | About the system
Installer and user reference guide
24
FXDA10~63A2VEB
VRV system air conditioner
4P599621-1A – 2020.10
a Indoor unit
b Outdoor unit
c User interface
d Suction air
e Discharge air
f Refrigerant piping + transmission cable
g Drain pipe
5.2 Information requirements for fan coil units
Item Symbol Value Unit
Cooling capacity (sensible) P
rated,c
A kW
Cooling capacity (latent) P
rated,c
B kW
Heating capacity P
rated,h
C kW
Total electric power input P
elec
D kW
Sound power level (per speed setting, if
applicable)
L
WA
E dB
Contact details:
DAIKIN INDUSTRIES CZECH REPUBLIC s.r.o. U Nové Hospody 1/1155, 301 00 Plzeň
Skvrňany, Czech Republic
A B C D E
FXDA10 0.8 0.3 1.3 0.036 48
FXDA15 1.2 0.5 1.9 0.048 50
FXDA20 1.5 0.7 2.5 0.068 51
FXDA25 1.9 0.9 3.2 0.068 51
FXDA32 2.5 1.1 4 0.068 51
FXDA40 3 1.5 5 0.075 52
FXDA50 3.8 1.8 6.3 0.096 53
FXDA63 4.8 2.3 8 0.107 54