OPERATION MANUAL
LRYEQ16A7Y1
LCBKQ3AV1(E)
CONVENI-PACK
4PEN448940-1A.book Page 1 Thursday, August 25, 2016 11:23 AM

Other manuals for Daikin LCBKQ3AV1

Questions and Answers

Overview

This document is an operation manual for the DAIKIN CONVENI-PACK, specifically for models LRYEQ16A7Y1 and LCBKQ3AV1(E). It provides detailed instructions and safety precautions for the use, maintenance, and troubleshooting of the unit.

Function Description:

The CONVENI-PACK is an appliance designed for expert or trained users in various settings such as shops, light industry, farms, and for commercial and household use. It functions as an all-in-one air-conditioner and refrigerator system, capable of cooling, heating, automatic operation, and fan-only operation. It also supports program dry operation to decrease humidity with minimal temperature reduction. The system can be controlled individually, in a group, or with two remote controllers for a single unit.

Important Technical Specifications:

  • Refrigerant Type: R410A, a fluorinated greenhouse gas.
  • Global Warming Potential (GWP) Value: 2087.5.
  • Power Supply:
    • LRYEQ16A7Y1: 3 phase 380~415V 50Hz.
    • LCBKQ3AV1(E): 1 phase 220~240V 50Hz.
  • Operating Conditions (Outdoor Unit):
    • Air-conditioning side: Indoor temperature 27°CDB/19°CWB, Outdoor temperature 32°CDB.
    • Cooling equipment side: Evaporating temperature -10°C, Outdoor temperature 32°CDB, Suction SH 10°C.
    • Heating conditions: Indoor temperature 20°CDB, Outdoor temperature 7°CDB/6°CWB.
  • Evaporating Temperature:
    • Refrigeration: -20°C~10°C.
    • Freezing (LCBKQ3AV1(E)): -45°C~-20°C.
  • Outdoor Temperature Range:
    • Cooling: -5°C~+43°CDB.
    • Heating: -15°C~21°CDB (LRYEQ16A7Y1), -15°C~15.5°CWB (LCBKQ3AV1(E)).
  • Capacity (kW):
    • LRYEQ16A7Y1: Air-conditioning 14, Refrigerating 21.8, Heating 27.
    • LCBKQ3AV1(E): Freezing 3.35.
  • Piping Length:
    • Connecting piping length (between indoor and outdoor unit): Within 130 m (LRYEQ16A7Y1), Within 30 m (LCBKQ3AV1(E)).
    • Height difference (between inside and outside units): Within 35 m (LRYEQ16A7Y1), Within 10 m (LCBKQ3AV1(E)).
    • Height difference (between inside units - Air-condition side): Within 0.5 m.
    • Height difference (between inside units - Showcase side): Within 5 m.
  • Design Pressure: High-pressure side 40 bar (4.0 MPa), Low-pressure side 25 bar (2.5 MPa).
  • Outer Dimensions (HxWxD):
    • LRYEQ16A7Y1: 1680x1240x765 mm.
    • LCBKQ3AV1(E): 480x680x310 mm.
  • Product Mass:
    • LRYEQ16A7Y1: 370 kg.
    • LCBKQ3AV1(E): 47 kg.
  • Sound Pressure Level:
    • LRYEQ16A7Y1: 62 dB(A).
    • LCBKQ3AV1(E): 49 dB(A).
  • Booster Unit (LCBKQ3AV1(E)): Evaporating temperature -35°C, Outdoor temperature 32°C, Suction SH 10°C, Saturated temperature to discharge pressure of booster unit -10°C.

Usage Features:

  • Remote Controller: The manual assumes a BRC1C62 remote controller (though BRC1E51A is also mentioned). It features an on/off button, operation lamp, display for changeover control, air flow flap, ventilation/air cleaning, set temperature, operation mode, programmed time, inspection/test operation, centralized control indicator, fan speed, air filter cleaning reminder, defrost/hot start indicator, timer mode start/stop, timer on/off, programming time, temperature setting, filter sign reset, fan speed control, operation mode selector, and air flow direction adjust buttons.
  • Operation Modes: Cooling, heating, automatic, fan only, and program dry.
  • Temperature Adjustment: Set desired temperature using the temperature setting button, adjustable in 1°C increments.
  • Fan Speed Control: Select preferred fan speed using the fan speed control button.
  • Air Flow Direction: Adjustable via the air flow direction adjust button, offering automatic swing or fixed positions.
  • Timer Operation: Program start and stop times up to 72 hours in advance.
  • Hot Start/Defrost Operation: Automatic functions to prevent cold air blowing during heating startup and to defrost the outdoor unit when ice builds up, indicated by specific symbols on the remote controller.
  • Safety Features: Automatic restart after power failure, compressor protection (5-minute delay before restarting), and automatic fan stop during defrost.
  • Group Control System: One remote controller can manage up to 16 indoor units simultaneously.
  • Two Remote Controller Control System: Two remote controllers can control one indoor unit (or one group of indoor units) individually.

Maintenance Features:

  • Regular Cleaning:
    • Outdoor Unit: Consult local dealer.
    • Indoor Unit: Stop operation with remote controller and cut off power breaker before cleaning. Refer to the indoor unit manual for details.
    • Showcase and Unit Cooler: Refer to their respective operation manuals.
    • Drain Pan (Optional Accessory): Clean to prevent clogging and dust.
  • Air Filter Cleaning: The remote controller displays a reminder when the air filter needs cleaning. A qualified service person should perform this.
  • Power Off for Long Periods: Turn off the main power supply switch if the unit is not used for a long time to prevent dust accumulation, heat generation, or ignition.
  • Pre-operation Power On: Turn on the main power switch 6 hours before resuming operation after a long period of being off to ensure smooth running and machine protection.
  • Periodic Inspections: Refrigerant leak inspections may be required by legislation. Contact the local dealer for more information.
  • Professional Maintenance: Disassembly and internal cleaning require specialized techniques. An authorized contractor from the dealer is recommended for maintenance inspections.
  • Troubleshooting Guide: Provides solutions for common issues such as the unit not operating, stopping sometimes, inability to change COOL/HEAT, fan operation without cooling/heating, incorrect fan strength, white mist, noise, and dust emission. It also includes checks to perform before requesting servicing, such as power supply, circuit breaker status, and obstruction of air inlets/outlets.
  • After-Sale Service: Instructions for requesting repairs, repairs after warranty expiration, maintenance inspection, relocation, and disposal. It emphasizes contacting the dealer for all these services, especially for handling refrigerant and ensuring proper installation/modification.