Description of the MicroTech® control system, HMI, and controllers.
Step-by-step guide for removing and re-attaching the compressor.
Strategies for controlling condenser water temperature for optimal chiller performance.
Instructions for field power wiring connections, including safety precautions.
Explanation of features for rapid restart and maintaining operation during power loss.
Schematic for field wiring connections, including options and notes.
Detailed wiring schematic for the WME unit.
General sequence of operation for Magnitude® WME chillers.
Options for overriding normal chiller operation via HMI, BAS, or manual buttons.
Details on operating the chiller without the HMI and navigation summary.
Overview of the Home View Screen, displaying basic operating conditions and consistent information.
Detailed view of unit parameters including compressor, evaporator, and condenser information.
Comprehensive display of compressor operating parameters and status.
Introduction to HMI setpoint screens for inputting various parameters.
Step-by-step guide on how to change setpoints using the HMI interface.
Settings related to water temperature, delta T, and reset types.
Settings for unit modes, control sources, and pump logic.
Settings related to motor operation, demand limits, and compressor staging.
Settings for cooling tower control strategies, fan staging, and valve control.
Explanation of different tower control strategies available.
Settings related to the expansion valve gain.
Settings for temperature and pressure offsets.
Settings related to alarms, including pressure and temperature thresholds.
Commissioning settings, including IP configuration and IGV calibration.
Settings for HMI interface, BAS protocols, and compressor capacity control.
How to access and view trend history data.
Explanation of alarm types (Critical and Warning) and how they are displayed.
Procedures for clearing alarms, including auto-clear and manual clearing.
Steps for downloading trend and alarm history data via USB.
Lists critical alarms, their triggers, and potential causes.
Overview of unit controller analog and digital inputs and outputs.
Overview of compressor controller analog inputs and digital/analog outputs.
Information on integrating chillers with BAS and available protocol options.
Instructions for installing and calibrating the thermal dispersion flow switch.
Continued instructions for flow switch setup, including range adjustment and locking.
General maintenance procedures, including electrical system and cleaning.